172 citations · 544 across the 9 of their papers we have counts for
9 papers
Position Reconstruction in the DEAP-3600 Dark Matter Search Experiment
The DEAP Collaboration, P. Adhikari, R. Ajaj +162
In the DEAP-3600 dark matter search experiment, precise reconstruction of the positions of scattering events in liquid argon is key for background rejection and defining a fiducial…
Precision Measurement of the Specific Activity of Ar in Atmospheric Argon with the DEAP-3600 Detector
P. Adhikari, R. Ajaj, M. Alpízar-Venegas +147
The specific activity of the beta decay of Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (…
Pulseshape discrimination against low-energy Ar-39 beta decays in liquid argon with 4.5 tonne-years of DEAP-3600 data
The DEAP Collaboration, P. Adhikari, R. Ajaj +126
The DEAP-3600 detector searches for the scintillation signal from dark matter particles scattering on a 3.3 tonne liquid argon target. The largest background comes from Ar b…
Search for dark matter with a 231-day exposure of liquid argon using DEAP-3600 at SNOLAB
R. Ajaj, P. -A. Amaudruz, G. R. Araujo +99
DEAP-3600 is a single-phase liquid argon (LAr) direct-detection dark matter experiment, operating 2 km underground at SNOLAB (Sudbury, Canada). The detector consists of 3279 kg of…
Design and Construction of the DEAP-3600 Dark Matter Detector
P. -A. Amaudruz, M. Baldwin, M. Batygov +106
The Dark matter Experiment using Argon Pulse-shape discrimination (DEAP) has been designed for a direct detection search for particle dark matter using a single-phase liquid argon…
First results from the DEAP-3600 dark matter search with argon at SNOLAB
3600 Collaboration, P. -A. Amaudruz, M. Baldwin +102
This paper reports the first results of a direct dark matter search with the DEAP-3600 single-phase liquid argon (LAr) detector. The experiment was performed 2 km underground at SN…
Improving Photoelectron Counting and Particle Identification in Scintillation Detectors with Bayesian Techniques
M. Akashi-Ronquest, P. -A. Amaudruz, M. Batygov +79
Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and…
Radon backgrounds in the DEAP-1 liquid-argon-based Dark Matter detector
P. -A. Amaudruz, M. Batygov, B. Beltran +49
The DEAP-1 \SI{7}{kg} single phase liquid argon scintillation detector was operated underground at SNOLAB in order to test the techniques and measure the backgrounds inherent to si…
Measurement of the scintillation time spectra and pulse-shape discrimination of low-energy beta and nuclear recoils in liquid argon with DEAP-1
P. -A. Amaudruz, M. Batygov, B. Beltran +69
The DEAP-1 low-background liquid argon detector was used to measure scintillation pulse shapes of electron and nuclear recoil events and to demonstrate the feasibility of pulse-sha…