activity
20122024
most citedPerspectives to measure neutrino-nuclear neutral current coherent scattering with two-phase emission detector

50 citations · 166 across the 9 of their papers we have counts for

collaborators

9 papers

hep-ex2024

First constraints on the coherent elastic scattering of reactor antineutrinos off xenon nuclei

D. Yu. Akimov, I. S. Alexandrov, V. A. Belov +18

RED-100 is a two-phase emission detector with an active volume containing 126~kg of liquid xenon. The detector was exposed to the antineutrino flux of about cm$…

physics.ins-det2024★ 2 cited

Calibration and characterization of the RED-100 detector at the Kalinin nuclear power plant

D. Yu. Akimov, I. S. Aleksandrov, F. B. Ata Kurbonova +20

RED-100 is a two-phase Xe detector designed and built for the study of coherent elastic neutrino-nucleus scattering CEvNS of reactor antineutrinos. A comprehensive calibration was…

physics.ins-det2023

Characterization of the ambient background in the RED-100 experiment location at Kalinin Nuclear Power Plant

D. Y. Akimov, I. S. Alexandrov, V. A. Belov +19

The RED-100 experiment with a liquid xenon target was carried out at Kalinin Nuclear Power Plant. The goal of the experiment is the detection and study of the coherent elastic neut…

physics.ins-det2022★ 26 cited

The RED-100 experiment

D. Yu. Akimov, I. S. Alexandrov, R. R. Alyev +21

The RED-100 two-phase xenon emission detector has been deployed at 19-m distance from the reactor core of the Kalinin Nuclear Power Plant (KNPP) in 2021 - 2022 for investigation of…

physics.ins-det2019★ 44 cited

First ground-level laboratory test of the two-phase xenon emission detector RED-100

D. Yu. Akimov, V. A. Belov, A. I. Bolozdynya +22

RED-100 is a two-phase detector for study of coherent elastic scattering of reactor electron antineutrinos off xenon atomic nuclei. The detector contains a total of 200 kg of liqui…

physics.ins-det2015★ 17 cited

Observation of light emission from Hamamatsu R11410-20 photomultiplier tubes

D. Yu. Akimov, A. I. Bolozdynya, Yu. V. Efremenko +4

We have shown that high voltage biased Hamamatsu R11410-20 photomultipliers with a dark count rate above 10 kHz emit single photons. The effect has been observed in a few units at…

physics.ins-det2014★ 21 cited

Experimental study of ionization yield of liquid xenon for electron recoils in the energy range 2.8 - 80 keV

D. Yu. Akimov, V. V. Afanasyev, I. S. Alexandrov +23

We present the results of the first experimental study of ionization yield of electron recoils with energies below 100 keV produced in liquid xenon by the isotopes: 37Ar, 83mKr, 24…

physics.ins-det2013★ 6 cited

Two-phase xenon emission detector with electron multiplier and optical readout by multipixel avalanche Geiger photodiodes

D. Yu. Akimov, A. V. Akindinov, I. S. Alexandrov +9

A successful operation of a new optical readout system (THGEM + WLS + MGPDs (multichannel array of multipixel avalanche Geiger photodiodes) in a two-phase liquid xenon detector was…

physics.ins-det2012★ 50 cited

Perspectives to measure neutrino-nuclear neutral current coherent scattering with two-phase emission detector

RED Collaboration, D. Yu. Akimov, I. S. Alexandrov +43

We propose to detect and to study neutrino neutral current coherent scattering off atomic nuclei with a two-phase emission detector using liquid xenon as a working medium. Expected…