activity
20142026
most citedFirst Dark Matter Search Results from the LUX-ZEPLIN (LZ) Experiment

747 citations · 1.9k across the 39 of their papers we have counts for

collaborators

41 papers

hep-ph2026

High-sensitivity Ultralight Dark Matter detector: Parametrically Amplified Casimir Devices

Muping Chen, Hideo Iizuka, Kyohei Mukaida +2

We propose the use of sphere-and-plate Casimir force measurement setups to detect ultralight vector dark matter. We demonstrate that sub-picometer signals can be parametrically amp…

hep-ex2026

Measurement of the cosmic muon flux at the Stawell Underground Physics Laboratory

G. Fu, M. Mews, F. Scutti +35

We report the first measurement of the underground cosmic muon flux at the Stawell Underground Physics Laboratory. The measurement uses eight EJ200 plastic scintillator panels, equ…

physics.ins-det2025★ 5 cited

Spontaneous generation of athermal phonon bursts within bulk silicon causing excess noise, low energy background events and quasiparticle poisoning in superconducting sensors

C. L. Chang, Y. -Y. Chang, M. Garcia-Sciveres +25

Solid state phonon detectors used in the search for dark matter and coherent neutrino nucleus interactions (CENS) require excellent energy resolution (eV-scale or below) and low…

physics.ins-det2025

Photomultiplier Requirements and Pre-Calibration for the SABRE South Liquid Scintillator Veto

L. J. Milligan, P. Urquijo, E. Barberio +32

We present a study of the oil-proof base Hamamatsu R5912 photomultiplier tubes that will be used in the SABRE South linear-alkylbenzene liquid scintillator veto. SABRE South is a d…

physics.ins-det2025★ 2 cited

Characterisation of Hamamatsu R11065-20 PMTs for use in the SABRE South NaI(Tl) Crystal Detectors

O. Stanley, W. J. D. Melbourne, P. Urquijo +31

The SABRE Experiment is a direct detection dark matter experiment using a target composed of multiple NaI(Tl) crystals. The experiment aims to be an independent check of the DAMA/L…

hep-ex2025★ 18 cited

First Limits on Light Dark Matter Interactions in a Low Threshold Two Channel Athermal Phonon Detector from the TESSERACT Collaboration

C. L. Chang, Y. -Y. Chang, L. Chaplinsky +45

We present results of a search for spin-independent dark matter-nucleon interactions in a 1 cm by 1 mm thick (0.233 gram) high-resolution silicon athermal phonon detector opera…

physics.ins-det2024★ 6 cited

The SABRE South Technical Design Report Executive Summary

E. Barberio, T. Baroncelli, V. U. Bashu +42

In this technical design report (TDR) executive summary we describe the SABRE South detector to be built at the Stawell Underground Physics Laboratory (SUPL). The SABRE South detec…

physics.ins-det2024★ 13 cited

Low Energy Backgrounds and Excess Noise in a Two-Channel Low-Threshold Calorimeter

Robin Anthony-Petersen, Clarence L. Chang, Yen-Yung Chang +29

We describe observations of low energy excess (LEE) events, background events observed in all light dark matter direct detection calorimeters, and noise in a Transition Edge Sensor…

nucl-ex2024★ 8 cited

Two-neutrino double electron capture of Xe in the first LUX-ZEPLIN exposure

J. Aalbers, D. S. Akerib, A. K. Al Musalhi +202

The broad physics reach of the LUX-ZEPLIN (LZ) experiment covers rare phenomena beyond the direct detection of dark matter. We report precise measurements of the extremely rare dec…

hep-ex2024★ 2 cited

The DAMA/LIBRA signal: an induced modulation effect?

R. S. James, K. Rule, E. Barberio +36

The persistence of the DAMA/LIBRA (DAMA) modulation over the past two decades has been a source of great contention within the dark matter community. The DAMA collaboration reports…

physics.ins-det2024★ 7 cited

The Design, Implementation, and Performance of the LZ Calibration Systems

J. Aalbers, D. S. Akerib, A. K. Al Musalhi +200

LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) i…

physics.ins-det2024★ 1 cited

The Data Acquisition System of the LZ Dark Matter Detector: FADR

J. Aalbers, D. S. Akerib, A. K. Al Musalhi +213

The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MH…

hep-ex2024★ 2 cited

Constraints On Covariant WIMP-Nucleon Effective Field Theory Interactions from the First Science Run of the LUX-ZEPLIN Experiment

J. Aalbers, D. S. Akerib, A. K. Al Musalhi +201

The first science run of the LUX-ZEPLIN (LZ) experiment, a dual-phase xenon time project chamber operating in the Sanford Underground Research Facility in South Dakota, USA, has re…

hep-ex2024★ 23 cited

New constraints on ultraheavy dark matter from the LZ experiment

J. Aalbers, D. S. Akerib, A. K. Al Musalhi +196

Searches for dark matter with liquid xenon time projection chamber experiments have traditionally focused on the region of the parameter space that is characteristic of weakly inte…

hep-ex2023★ 20 cited

First Constraints on WIMP-Nucleon Effective Field Theory Couplings in an Extended Energy Region From LUX-ZEPLIN

LZ Collaboration, J. Aalbers, D. S. Akerib +197

Following the first science results of the LUX-ZEPLIN (LZ) experiment, a dual-phase xenon time projection chamber operating from the Sanford Underground Research Facility in Lead,…

hep-ex2023★ 56 cited

A search for new physics in low-energy electron recoils from the first LZ exposure

The LZ Collaboration, J. Aalbers, D. S. Akerib +200

The LUX-ZEPLIN (LZ) experiment is a dark matter detector centered on a dual-phase xenon time projection chamber. We report searches for new physics appearing through few-keV-scale…

physics.ins-det2023★ 13 cited

First Demonstration of the HeRALD Superfluid Helium Detector Concept

R. Anthony-Petersen, A. Biekert, C. L. Chang +33

The SPICE/HeRALD collaboration is performing R&D to enable studies of sub-GeV dark matter models using a variety of target materials. Here we report our recent progress on instrume…

physics.ins-det2023★ 2 cited

A portable and high intensity 24 keV neutron source based on Sb-Be photoneutrons and an iron filter

A. Biekert, C. Chang, L. Chaplinsky +27

A portable monoenergetic 24 keV neutron source based on the Sb-Be photoneutron reaction and an iron filter has been constructed and characterized. The coincidence of th…

hep-ex2022★ 38 cited

Background Determination for the LUX-ZEPLIN (LZ) Dark Matter Experiment

J. Aalbers, D. S. Akerib, A. K. Al Musalhi +200

The LUX-ZEPLIN experiment recently reported limits on WIMP-nucleus interactions from its initial science run, down to cm for the spin-independent interactio…

physics.ins-det2022★ 30 cited

A Stress Induced Source of Phonon Bursts and Quasiparticle Poisoning

Robin Anthony-Petersen, Andreas Biekert, Raymond Bunker +43

The performance of superconducting qubits is degraded by a poorly characterized set of energy sources breaking the Cooper pairs responsible for superconductivity, creating a condit…

hep-ex2022★ 747 cited

First Dark Matter Search Results from the LUX-ZEPLIN (LZ) Experiment

J. Aalbers, D. S. Akerib, C. W. Akerlof +344

The LUX-ZEPLIN experiment is a dark matter detector centered on a dual-phase xenon time projection chamber operating at the Sanford Underground Research Facility in Lead, South Dak…

physics.ins-det2022★ 11 cited

Performance of the SABRE detector module in a purely passive shielding

F. Calaprice, J. B. Benziger, S. Copello +19

We present here a characterization of the low background NaI(Tl) crystal NaI-33 based on a period of almost one year of data taking (891 kgxdays exposure) in a detector configurati…

hep-ex2022★ 2 cited

Snowmass2021 Cosmic Frontier White Paper: Calibrations and backgrounds for dark matter direct detection

Daniel Baxter, Raymond Bunker, Sally Shaw +48

Future dark matter direct detection experiments will reach unprecedented levels of sensitivity. Achieving this sensitivity will require more precise models of signal and background…

physics.ins-det2022★ 2 cited

A backing detector for order-keV neutrons

A. Biekert, L. Chaplinsky, C. W. Fink +23

We have designed and tested a large-area (0.15~m) neutron detector based on neutron capture on \ce{^{6}Li}. The neutron detector design has been optimized for the purpose of ta…