First Limits on Light Dark Matter Interactions in a Low Threshold Two Channel Athermal Phonon Detector from the TESSERACT Collaboration
arXiv:2503.03683 · doi:10.1103/hsrl-crvf
Abstract
We present results of a search for spin-independent dark matter-nucleon interactions in a 1 cm by 1 mm thick (0.233 gram) high-resolution silicon athermal phonon detector operated above ground. For interactions in the substrate, this detector achieves a r.m.s. baseline energy resolution of 361.5 0.4 MeV/, the best for any athermal phonon detector to date. With an exposure of 0.233g 12 hours, we place the most stringent constraints on dark matter masses between 44 and 87 MeV/, with the lowest unexplored cross section of 4 cm at 87 MeV/. We employ a conservative salting technique to reach the lowest dark matter mass ever probed via direct detection experiment. This constraint is enabled by two-channel rejection of low-energy backgrounds that are coupled to individual sensors.
8 total pages, 5 figures, 2 appendices
References in corpus (22)
- First results from the CRESST-III low-mass dark matter program
- Milky Way Satellite Census. III. Constraints on Dark Matter Properties from Observations of Milky Way Satellite Galaxies
- Finding an Upper Limit in the Presence of Unknown Background
- Novel direct detection constraints on light dark matter
- Constraints on scattering of keV--TeV dark matter with protons in the early Universe
- Light Dark Matter Search with a High-Resolution Athermal Phonon Detector Operated Above Ground
- Strong New Limits on Light Dark Matter from Neutrino Experiments
- EXCESS workshop: Descriptions of rising low-energy spectra
- Earth-Scattering of super-heavy Dark Matter: updated constraints from detectors old and new
- A Path to the Direct Detection of sub-GeV Dark Matter Using Calorimetric Readout of a Superfluid He Target
- New limits on light dark matter - proton cross section from the cosmic large-scale structure
- Sources of Low-Energy Events in Low-Threshold Dark Matter and Neutrino Detectors
- A Stress Induced Source of Phonon Bursts and Quasiparticle Poisoning
- Dark Matter Induced Power in Quantum Devices
- Observation of a nuclear recoil peak at the 100 eV scale induced by neutron capture
- Low Energy Backgrounds and Excess Noise in a Two-Channel Low-Threshold Calorimeter
- First Demonstration of the HeRALD Superfluid Helium Detector Concept
- DoubleTES detectors to investigate the CRESST low energy background: results from above-ground prototypes
- Measurement Of Quasiparticle Transport In Aluminum Films Using Tungsten Transition-Edge Sensors
- Aluminum Relaxation as the Source of Excess Low Energy Events in Low Threshold Calorimeters
- A Transition Edge Sensor Operated in Coincidence with a High Sensitivity Athermal Phonon Sensor for Photon Coupled Rare Event Searches
- Observation of a low energy nuclear recoil peak in the neutron calibration data of the CRESST-III Experiment
Cited by in corpus (7)
- Spontaneous generation of athermal phonon bursts within bulk silicon causing excess noise, low energy background events and quasiparticle poisoning in superconducting sensors
- Boosted dark matter versus dark matter-induced neutrinos from single and stacked blazars
- Probing Cosmic Neutrino Background through Parametric Fluorescence
- Hydrogenated carbon structures as directional sub-GeV dark matter detectors
- First direct search for light dark matter interactions in a transition-edge sensor
- Constraints on sub-GeV dark matter scattering on electrons with COSINE-100
- State of the Art in Direct Dark Matter Detectors: Technologies, Performance, and Future Directions