most citedSimulating NEMA characteristics of the modular total-body J-PET scanner -- an economic total-body PET from plastic scintillators

105 citations · 134 across the 9 of their papers we have counts for

collaborators

9 papers

physics.med-ph2024

Investigation of Novel Preclinical Total Body PET Designed With J-PET Technology:A Simulation Study

M. Dadgar, S. Parzych, F. Tayefi Ardebili +29

The growing interest in human-grade total body positron emission tomography (PET) systems has also application in small animal research. Due to the existing limitations in human-ba…

physics.ins-det2024★ 12 cited

Comparative studies of plastic scintillator strips with high technical attenuation length for the total-body J-PET scanner

L. Kaplon, J. Baran, N. Chug +31

Plastic scintillator strips are considered as one of the promising solutions for the cost-effective construction of total-body positron emission tomography, (PET) system. The purpo…

physics.med-ph2023

Feasibility of the J-PET to monitor range of therapeutic proton beams

Jakub Baran, Damian Borys, Karol Brzeziński +40

Objective: The aim of this work is to investigate the feasibility of the Jagiellonian Positron Emission Tomography (J-PET) scanner for intra-treatment proton beam range monitoring.…

physics.med-ph2023★ 3 cited

TOF MLEM Adaptation for the Total-Body J-PET with a Realistic Analytical System Response Matrix

R. Y. Shopa, J. Baran, K. Klimaszewski +32

We report a study of the original image reconstruction algorithm based on the time-of-flight maximum likelihood expectation maximisation (TOF MLEM), developed for the total-body (T…

physics.ins-det2023★ 6 cited

J-PET detection modules based on plastic scintillators for performing studies with positron and positronium beams

S. Sharma, J. Baran, R. S. Brusa +33

The J-PET detector, which consists of inexpensive plastic scintillators, has demonstrated its potential in the study of fundamental physics. In recent years, a prototype with 192 p…

physics.med-ph2022★ 2 cited

Realistic Total-Body J-PET Geometry Optimization -- Monte Carlo Study

Jakub Baran, Wojciech Krzemien, Lech Raczyński +31

Total-Body PET is one of the most promising medical diagnostics modalities. The high sensitivity provided by Total-Body technology can be advantageous for novel tomography methods…

physics.med-ph2022★ 2 cited

Development of the normalization method for the Jagiellonian PET scanner

Aurélien Coussat, Wojciech Krzemien, Jakub Baran +1

This work aims at applying the theory of the component-based normalization for the Jagiellonian PET scanner, currently under development at the Jagiellonian University. In any Posi…

physics.ins-det2021★ 105 cited

Simulating NEMA characteristics of the modular total-body J-PET scanner -- an economic total-body PET from plastic scintillators

Paweł Moskal, Paweł Kowalski, Roman Shopa +26

The purpose of the presented research is estimation of the performance characteristics of the economic Total-Body Jagiellonian-PET system (TB-J-PET) constructed from plastic scinti…

physics.med-ph2019★ 4 cited

Investigations on physical and biological range uncertainties in Krakow proton beam therapy centre

Antoni Rucinski, Jakub Baran, Giuseppe Battistoni +15

Physical and biological range uncertainties limit the clinical potential of Proton Beam Therapy (PBT). In this proceedings, we report on two research projects, which we are conduct…