685 citations · 6.5k across the 94 of their papers we have counts for
9 papers · 1 filter
Tapered nanofiber trapping of high-refractive-index nanoparticles
Jon D. Swaim, Joachim Knittel, Warwick P. Bowen
A nanofiber-based optical tweezer is demonstrated. Trapping is achieved by combining attractive near-field optical gradient forces with repulsive electrostatic forces. Silica-coate…
Back-scatter based whispering gallery mode sensing
Joachim Knittel, Jon D. Swaim, David L. McAuslan +2
Whispering gallery mode biosensors allow selective unlabelled detection of single proteins and, combined with quantum limited sensitivity, the possibility for noninvasive realtime…
Optomechanical parameter estimation
Shan Zheng Ang, Glen I. Harris, Warwick P. Bowen +1
We propose a statistical framework for the problem of parameter estimation from a noisy optomechanical system. The Cramér-Rao lower bound on the estimation errors in the long-time…
Entangled Mechanical Cat States via Conditional Single Photon Optomechanics
Uzma Akram, Warwick P. Bowen, Gerard J. Milburn
We study single photon optomechanics conditioned on photon counting events. By selecting only detection events that occur long after a photon pulse arrives at the cavity, the optom…
Subdiffraction-limited quantum imaging within a living cell
Michael A. Taylor, Jiri Janousek, Vincent Daria +4
We report both sub-diffraction-limited quantum metrology and quantum enhanced spatial resolution for the first time in a biological context. Nanoparticles are tracked with quantum…
Minimum requirements for feedback enhanced force sensing
Glen I. Harris, David L. McAuslan, Thomas M. Stace +2
The problem of estimating an unknown force driving a linear oscillator is revisited. When using linear measurement, feedback is often cited as a mechanism to enhance bandwidth or s…
Detection of Nanoparticles with a Frequency Locked Whispering Gallery Mode Microresonator
Jon D. Swaim, Joachim Knittel, Warwick P. Bowen
We detect 39 nm x 10 nm gold nanorods using a microtoroid stabilized via the Pound-Drever-Hall method. Real-time detection is achieved with signal-to-noise ratios up to 12.2. These…
Quantum-enhanced micro-mechanical displacement sensitivity
Ulrich B. Hoff, Glen I. Harris, Lars S. Madsen +5
We report on a hitherto unexplored application of squeezed light: for quantum-enhancement of mechanical transduction sensitivity in microcavity optomechanics. Using a toroidal sili…
Optical lock-in particle tracking in optical tweezers
Michael A Taylor, Joachim Knittel, Warwick P Bowen
We demonstrate a lock-in particle tracking scheme in optical tweezers based on stroboscopic modulation of an illuminating optical field. This scheme is found to evade low frequency…