activity
20002026
most citedSearch for Low-Mass WIMPs with SuperCDMS

529 citations · 2.7k across the 54 of their papers we have counts for

collaborators
Showing physics.ins-detShow all

22 papers · 1 filter

physics.ins-det2026

Cryogenic characterisation of the FBK NUV-HD-cryo Silicon Photomultipliers for the DarkSide-20k dark matter experiment

F. Acerbi, P. Adhikari, P. Agnes +298

Liquid Argon Time Projection Chambers (TPCs) are highly promising detectors for dark matter searches due to their uniform response, scalability to large target masses, and compatib…

physics.ins-det2024★ 4 cited

Benchmarking the design of the cryogenics system for the underground argon in DarkSide-20k

20k Collaboration, F. Acerbi, P. Adhikari +315

DarkSide-20k (DS-20k) is a dark matter detection experiment under construction at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It utilises ~100 t of low radioactivity a…

physics.ins-det2024

Temperature-Dependent Photoluminescence of PEDOT:PSS for use as Transparent Electrodes in the DarkSide-20k Time Projection Chamber

Nicholas Swidinsky, Emma Ellingwood, Jonathan Hucker +7

Dual-phase time-projection chambers (TPCs) filled with noble elements are used for particle detection, with many focusing on rare-event searches. These detectors measure two signal…

physics.ins-det2024★ 2 cited

Relative Measurement and Extrapolation of the Scintillation Quenching Factor of -Particles in Liquid Argon using DEAP-3600 Data

DEAP Collaboration, P. Adhikari, M. Alpízar-Venegas +101

The knowledge of scintillation quenching of -particles plays a paramount role in understanding -induced backgrounds and improving the sensitivity of liquid argon-based direct…

physics.ins-det2024★ 2 cited

A new hybrid gadolinium nanoparticles-loaded polymeric material for neutron detection in rare event searches

20k Collaboration, F. Acerbi, P. Adhikari +311

Experiments aimed at direct searches for WIMP dark matter require highly effective reduction of backgrounds and control of any residual radioactive contamination. In particular, ne…

physics.ins-det2023★ 11 cited

Array of Cryogenic Calorimeters to Evaluate the Spectral Shape of forbidden -decays: the ACCESS project

L. Pagnanini, G. Benato, P. Carniti +21

The ACCESS (Array of Cryogenic Calorimeters to Evaluate Spectral Shapes) project aims to establish a novel technique to perform precision measurements of forbidden \b{eta}-decays,…

physics.ins-det2023★ 14 cited

Precision Measurement of the Specific Activity of Ar in Atmospheric Argon with the DEAP-3600 Detector

P. Adhikari, R. Ajaj, M. Alpízar-Venegas +147

The specific activity of the beta decay of Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (…

physics.ins-det2023★ 14 cited

Measurement of isotopic separation of argon with the prototype of the cryogenic distillation plant Aria for dark matter searches

20k Collaboration

The Aria cryogenic distillation plant, located in Sardinia, Italy, is a key component of the DarkSide-20k experimental program for WIMP dark matter searches at the INFN Laboratori…

physics.ins-det2021★ 4 cited

Investigation of the cryogenic scintillation of pure and doped sodium-iodine

M. Clark, F. Froborg, P. C. F. Di Stefano +1

We have studied the scintillation of pure and doped sodium iodide crystals handled in low humidity conditions under external and excitation from room temperature down to 4K…

physics.ins-det2021★ 7 cited

Ultraviolet-induced fluorescence of poly(methyl methacrylate) compared to 1,1,4,4-tetraphenyl-1,3-butadiene down to 4 K

E. Ellingwood, H. Benmansour, Q. Hars +16

Several particle-physics experiments use poly(methyl methacrylate) (a.k.a. PMMA or acrylic) vessels to contain liquid scintillators. Superluminal charged particles emitted from rad…

physics.ins-det2021★ 2 cited

Fluorescence of pyrene-doped polystyrene films from room temperature down to 4 K for wavelength-shifting applications

H. Benmansour, E. Ellingwood, Q. Hars +13

In liquid argon-based particle detectors, slow wavelength shifters (WLSs) could be used alongside the common, nanosecond scale, WLS tetraphenyl butadiene (TPB) for background mitig…

physics.ins-det2021★ 7 cited

Development and characterization of a slow wavelength shifting coating for background rejection in liquid argon detectors

D. Gallacher, A. Leonhardt, H. Benmansour +15

We describe a technique, applicable to liquid-argon-based dark matter detectors, allowing for discrimination of alpha-decays in detector regions with incomplete light collection fr…

physics.ins-det2021★ 35 cited

Pulseshape discrimination against low-energy Ar-39 beta decays in liquid argon with 4.5 tonne-years of DEAP-3600 data

The DEAP Collaboration, P. Adhikari, R. Ajaj +126

The DEAP-3600 detector searches for the scintillation signal from dark matter particles scattering on a 3.3 tonne liquid argon target. The largest background comes from Ar b…

physics.ins-det2019★ 36 cited

Precision laser-based measurements of the single electron response of SPCs for the NEWS-G light dark matter search experiment

G Collaboration, Q. Arnaud, J. -P. Bard +36

Spherical Proportional Counters (SPCs) are a novel gaseous detector technology employed by the NEWS-G low-mass dark matter search experiment for their high sensitivity to single el…

physics.ins-det2018★ 6 cited

Energy Loss Due to Defect Formation from Pb Recoils in SuperCDMS Germanium Detectors

Robert Agnese, Taylor Aralis, Tsuguo Aramaki +94

The Super Cryogenic Dark Matter Search experiment (SuperCDMS) at the Soudan Underground Laboratory studied energy loss associated with Frenkel defect formation in germanium crystal…

physics.ins-det2018★ 20 cited

Nuclear-recoil energy scale in CDMS II silicon dark-matter detectors

R. Agnese, A. J. Anderson, T. Aramaki +106

The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark matter particles that elastically scatter from nuclei in semiconductor detectors. The resulting nuclear-re…

physics.ins-det2017★ 16 cited

Particle detection at cryogenic temperatures with undoped CsI

Michael Clark, Patrick Nadeau, Shane Hills +2

Scintillation at cryogenic temperatures can give rise to detectors with particle discrimination for rare-event searches such as dark matter detection. We present time-resolved scin…

physics.ins-det2016

A Multi-Channel Setup to Study Fractures in Scintillators

A. Tantot, C. Bouard, R. Briche +6

To investigate fractoluminescence in scintillating crystals used for particle detection, we have developed a multi-channel setup built around samples of double-cleavage drilled com…

physics.ins-det2015★ 1 cited

Low-Temperature Scintillation Properties of CaWO4 Crystals for Rare-Event Searches

M. v. Sivers, M. Clark, P. C. F. Di Stefano +13

In prospect of its application in cryogenic rare-event searches, we have investigated the low-temperature scintillation properties of CaWO4 crystals down to 3.4 K under α and γ exc…

physics.ins-det2014★ 11 cited

Sensitivity of alkali halide scintillating calorimeters with particle identification to investigate the DAMA dark matter detection claim

Patrick Nadeau, Michael Clark, P. C. F. Di Stefano +4

Scintillating calorimeters are cryogenic detectors combining a measurement of scintillation with one of phonons to provide particle identification. In view of developing alkali hal…

physics.ins-det2013★ 288 cited

CDMSlite: A Search for Low-Mass WIMPs using Voltage-Assisted Calorimetric Ionization Detection in the SuperCDMS Experiment

R. Agnese, A. J. Anderson, M. Asai +77

SuperCDMS is an experiment designed to directly detect Weakly Interacting Massive Particles (WIMPs), a favored candidate for dark matter ubiquitous in the Universe. In this paper,…

physics.ins-det2012★ 4 cited

Counting photons at low temperature with a streaming time-to-digital converter

P. C. F. Di Stefano, P. Nadeau, C. J. G. Onderwater +2

We present some aspects of photon counting to study scintillators at low temperatures. A time-to-digital converter (TDC) had been configured to acquire several-minute-long streams…