529 citations · 2.7k across the 54 of their papers we have counts for
9 papers · 1 filter
First direct detection constraints on Planck-scale mass dark matter with multiple-scatter signatures using the DEAP-3600 detector
P. Adhikari, R. Ajaj, M. Alpízar-Venegas +94
Dark matter particles with Planck-scale mass () arise in well-motivated theories and could be produced by several cosmological mechanisms. Using a blin…
Constraints on dark matter-nucleon effective couplings in the presence of kinematically distinct halo substructures using the DEAP-3600 detector
P. Adhikari, R. Ajaj, C. E. Bina +81
DEAP-3600 is a single-phase liquid argon detector aiming to directly detect Weakly Interacting Massive Particles (WIMPs), located at SNOLAB (Sudbury, Canada). After analyzing data…
Low-Mass Dark Matter Search with CDMSlite
SuperCDMS Collaboration, R. Agnese, A. J. Anderson +105
The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the…
WIMP-Search Results from the Second CDMSlite Run
SuperCDMS Collaboration, R. Agnese, A. J. Anderson +87
The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic germanium detectors operated at a relatively high bias voltage to amplify the phonon signal in the search for…
Dark matter effective field theory scattering in direct detection experiments
K. Schneck, B. Cabrera, D. G. Cerdeno +84
We examine the consequences of the effective field theory (EFT) of dark matter-nucleon scattering for current and proposed direct detection experiments. Exclusion limits on EFT cou…
Silicon detector results from the first five-tower run of CDMS II
CDMS Collaboration, R. Agnese, Z. Ahmed +87
We report results of a search for Weakly Interacting Massive Particles (WIMPs) with the Si detectors of the CDMS II experiment. This report describes a blind analysis of the first…
Search for annual modulation in low-energy CDMS-II data
CDMS Collaboration, Z. Ahmed, D. S. Akerib +64
We report limits on annual modulation of the low-energy event rate from the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory. Such a modulatio…
Combined Limits on WIMPs from the CDMS and EDELWEISS Experiments
CDMS, EDELWEISS Collaborations, : +114
The CDMS and EDELWEISS collaborations have combined the results of their direct searches for dark matter using cryogenic germanium detectors. The total data set represents 614 kg.d…
First results of the EDELWEISS-II WIMP search using Ge cryogenic detectors with interleaved electrodes
E. Armengaud, C. Augier, A. Benoit +41
The EDELWEISS-II collaboration has performed a direct search for WIMP dark matter with an array of ten 400 g heat-and-ionization cryogenic detectors equipped with interleaved elect…