Single-Spin Measurement and Decoherence in Magnetic Resonance Force Microscopy
arXiv:quant-ph/0210043 · doi:10.1103/PhysRevB.67.094425
Abstract
We consider a simple version of a cyclic adiabatic inversion (CAI) technique in magnetic resonance force microscopy (MRFM). We study the problem: What component of the spin is measured in the CAI MRFM? We show that the non-destructive detection of the cantilever vibrations provides a measurement of the spin component along the effective magnetic field. This result is based on numerical simulations of the Hamiltonian dynamics (the Schrodinger equation) and the numerical solution of the master equation.
5 pages + 5 figures (PNG format)
Cited by in corpus (12)
- Global control and fast solid-state donor electron spin quantum computing
- Analogue of Cavity QED for Coupling between Spin and Nanomechanical Resonator
- Localization Properties of Quantized Magnetostatic Modes in Nanocubes
- Realistic simulations of single-spin nondemolition measurement by magnetic resonance force microscopy
- Cooling a magnetic resonance force microscope via the dynamical back-action of nuclear spins
- Quantum Dissipative Dynamics of the Magnetic Resonance Force Microscope in the Single-Spin Detection Limit
- Stray Field Magnetic Resonance Tomography using Ferromagnetic Spheres
- Nanomagnetic Planar Magnetic Resonance Microscopy Lens
- Modeling and Simulations of a Single-Spin Measurement using MRFM
- A Model for Quantum Jumps in Magnetic Resonance Force Microscopy
- Quantum dynamics in single spin measurement
- Gaussian approximation and single-spin measurement in OSCAR MRFM with spin noise