Space charge in ionization detectors and the NA48 calorimeter
arXiv:hep-ex/9909025 · doi:10.1016/S0168-9002(98)01193-0
Abstract
The effects of space charge due to slowly drifting ions can be relevant for detectors operated at high intensity, or for relatively low values of the bias voltage. Accurate measurements have been obtained with the liquid krypton calorimeter of the NA48 experiment, from data collected in 1997. The build-up of space charge takes place during the first part of the beam extraction burst, and causes a dependence of the response on the transverse coordinate of the axis of electromagnetic showers, and a small reduction of average amplitude. The effects are well reproduced by a computation, where the only free parameter is the value of the ion mobility. The model can be applied a wide range of operating conditions, and generalized to detectors with different geometry and active medium.
arXiv comment11 pages, 11 figures, talk presented at CALOR99
Cited by in corpus (14)
- A new measurement of direct CP violation in two pion decays of the neutral kaon
- Muon momentum measurement in ICARUS-T600 LAr-TPC via multiple scattering in few-GeV range
- New measurements of the and masses
- Ionization Chambers for Monitoring in High-Intensity Charged Particle Beams
- Space charge in drift chambers operated with the Xe,CO2(15%) mixture
- Design and operation of LongBo: a 2 m long drift liquid argon TPC
- Space charge in liquid argon time-projection chambers: a review of analytical and numerical models, and mitigation methods
- Beam Tests of Ionization Chambers for the NuMI Neutrino Beam
- Design and performance of a 35-ton liquid argon time projection chamber as a prototype for future very large detectors
- A time dependent solution for the operation of ion chambers in a high ionization background
- Study of space charge in the ICARUS T600 detector
- Space Charge Effects in Noble Liquid Calorimeters and Time Projection Chambers
- Experimental study of the positive ion feedback from gas to liquid in a dual-phase argon chamber and measurement of the ion mobility in argon gas
- Calibration of calorimetric measurement in a liquid argon time projection chamber