Calibration of calorimetric measurement in a liquid argon time projection chamber
arXiv:2012.01319 · doi:10.3390/instruments5010002
Abstract
The liquid argon time projection chamber provides high resolution event images and excellent calorimetric resolution for studying neutrino physics and searching for beyond standard model physics. In this article, we review the main physics processes that affect the detector response, including the electronics and field responses, space charge effects, electron attachment to impurities, diffusion and recombination. We describe methods to measure those effects, which are used to calibrate the detector response and convert the measured raw ADC counts to the original energy deposition.
arXiv comment15 pages, 8 figures, submitted to Instruments
References in corpus (22)
- Design and Construction of the MicroBooNE Detector
- The ArgoNeuT Detector in the NuMI Low-Energy beam line at Fermilab
- First results on ProtoDUNE-SP liquid argon time projection chamber performance from a beam test at the CERN Neutrino Platform
- A study of electron recombination using highly ionizing particles in the ArgoNeuT Liquid Argon TPC
- Ionization Electron Signal Processing in Single Phase LArTPCs I. Algorithm Description and Quantitative Evaluation with MicroBooNE Simulation
- Calibration of the charge and energy loss per unit length of the MicroBooNE liquid argon time projection chamber using muons and protons
- Measurement of the muon decay spectrum with the ICARUS liquid Argon TPC
- Measurement of Longitudinal Electron Diffusion in Liquid Argon
- A Method to Determine the Electric Field of Liquid Argon Time Projection Chambers Using a UV Laser System and its Application in MicroBooNE
- Measurement of Space Charge Effects in the MicroBooNE LArTPC Using Cosmic Muons
- Michel Electron Reconstruction Using Cosmic-Ray Data from the MicroBooNE LArTPC
- A Measurement of the Absorption of Liquid Argon Scintillation Light by Dissolved Nitrogen at the Part-Per-Million Level
- The Liquid Argon Purity Demonstrator
- Calorimetry for low-energy electrons using charge and light in liquid argon
- A Regenerable Filter for Liquid Argon Purification
- Space charge in ionization detectors and the NA48 calorimeter
- Liquid Argon TPC Signal Formation, Signal Processing and Hit Reconstruction
- The Liquid Argon In A Testbeam (LArIAT) Experiment
- Status and New Ideas Regarding Liquid Argon Detectors
- Design and operation of LongBo: a 2 m long drift liquid argon TPC
- Space charge in liquid argon time-projection chambers: a review of analytical and numerical models, and mitigation methods
- Study of space charge in the ICARUS T600 detector