Improved Magnetic Information Storage using Return-Point Memory
arXiv:cond-mat/9610036 · doi:10.1063/1.364088
Abstract
The traditional magnetic storage mechanisms (both analog and digital) apply an external field signal H(t) to a hysteretic magnetic material, and read the remanent magnetization M(t), which is (roughly) proportional to H(t). We propose a new analog method of recovering the signal from the magnetic material, making use of the shape of the hysteresis loop M(H). The field H, ``stored'' in a region with N domains or particles, can be recovered with fluctuations of order 1/N using the new method - much superior to the 1/sqrt{N} fluctuations in traditional analog storage.
9 pages, 15 figures
References in corpus (3)
Cited by in corpus (9)
- Crackling Noise
- Memory formation in matter
- Endogenous Versus Exogenous Shocks in Complex Networks: an Empirical Test Using Book Sale Ranking
- Memory from coupled instabilities in unfolded crumpled sheets
- Topology of the energy landscape of sheared amorphous solids and the irreversibility transition
- State transition graph of the Preisach model and the role of return point memory
- Mechanical annealing and memories in a disordered solid
- Low-Temperature Glassy Response of Ultrathin Manganite Films to Electric and Magnetic Fields
- Evidence of Athermal Metastable Phase in a Halide Perovskite: Optically Tracked Thermal-Breach Memory