Extreme adaptive optics imaging with a clear and well-corrected off-axis telescope sub-aperture
arXiv:astro-ph/0702592 · doi:10.1086/511949
Abstract
Rather than using an adaptive optics (AO) system to correct a telescope s entire pupil, it can instead be used to more finely correct a smaller sub-aperture. Indeed, existing AO systems can be used to correct a sub-aperture 1/3 to 1/2 the size of a 5-10 m telescope to extreme adaptive optics (ExAO) levels. We discuss the potential performance of a clear off-axis well-corrected sub-aperture (WCS), and describe our initial imaging results with a 1.5 m diameter WCS on the Palomar Observatory s Hale telescope. These include measured Strehl ratios of 0.92-0.94 in the infrared (2.17 microns), and 0.12 in the B band, the latter allowing a binary of separation 0.34 arc sec to be easily resolved in the blue. Such performance levels enable a variety of novel observational modes, such as infrared ExAO, visible-wavelength AO, and high-contrast coronagraphy. One specific application suggested by the high Strehl ratio stability obtained (1%) is the measurement of planetary transits and eclipses. Also described is a simple dark-hole experiment carried out on a binary star, in which a comatic phase term was applied directly to the deformable mirror, in order to shift the diffraction rings to one side of the point spread function.
accepted by ApJ
References in corpus (9)
- Detection of Thermal Emission from an Extrasolar Planet
- Infrared radiation from an extrasolar planet
- Theoretical Limits on Extrasolar Terrestrial Planet Detection with Coronagraphs
- A Theory of Extrasolar Giant Planets
- High Dynamic Range Imaging Using a Deformable Mirror for Space Coronography
- Ground-Based Coronagraphy with High Order Adaptive Optics
- Direct Detection of the Brown Dwarf GJ 802B with Adaptive Optics Masking Interferometry
- Speckle nulling for exoplanet detection with space-based coronagraphic telescopes
- Telescope to Observe Planetary Systems (TOPS): a high throughput 1.2-m visible telescope with a small inner working angle
Cited by in corpus (17)
- Optical Vectorial Vortex Coronagraphs using Liquid Crystal Polymers: theory, manufacturing and laboratory demonstration
- The Vector Vortex Coronagraph: Laboratory Results and First Light at Palomar Observatory
- Review of small-angle coronagraphic techniques in the wake of ground-based second-generation adaptive optics systems
- High Performance Lyot and PIAA Coronagraphy for Arbitrarily shaped Telescope Apertures
- High-Contrast Observations in Optical and Infrared Astronomy
- Post-coronagraphic tip-tilt sensing for vortex phase masks: the QACITS technique
- Comparative Lyot Coronagraphy with Extreme AO Systems
- A dim candidate companion to εCephei
- Astrophotonics: astronomy and modern optics
- Performance of the extreme-AO instrument VLT/SPHERE and dependence on the atmospheric conditions
- Closure Phase Signatures of Planet Transit Events
- Imaging faint brown dwarf companions close to bright stars with a small, well-corrected telescope aperture
- On-Sky Demonstration of a Linear Band-limited Mask with Application to Visual Binary Stars
- A dual-mask coronagraph for observing faint companions to binary stars
- Adaptive optics in high-contrast imaging
- Orbital Solution and Dynamical Masses for the Nearby Binary System Gls 67 AB
- Zernike amplitude pupil apodization for vortex coronagraphy with obscured apertures