paper

Assessment of the Fluorescence and Auger Data Base used in Plasma Modeling

arXiv:astro-ph/0304200 · doi:10.1086/375561

Abstract

We have investigated the accuracy of the 1s-vacancy fluorescence data base of Kaastra & Mewe (1993, A&AS, 97, 443) resulting from the initial atomic physics calculations and the subsequent scaling along isoelectronic sequences. In particular, we have focused on the relatively simple Be-like and F-like 1s-vacancy sequences. We find that the earlier atomic physics calculations for the oscillator strengths and autoionization rates of singly-charged B II and Ne II are in sufficient agreement with our present calculations. However, the substantial charge dependence of these quantities along each isoelectronic sequence, the incorrect configuration averaging used for B II, and the neglect of spin-orbit effects (which become important at high-Z) all cast doubt on the reliability of the Kaastra & Mewe data for application to plasma modeling.

19 pages with 6 figures, AAS TeX, accepted for publication in ApJ