Optical Calibration of a Frequency-Domain-Multiplexed X-Ray TES Microcalorimeter Array via Photon-Number-Resolved Statistics
arXiv:2610.40194 · doi:10.3390/s26216788
Abstract
Transition-edge sensor (TES) microcalorimeters for future X-ray space observatories require accurate low-energy calibration, a regime where conventional X-ray sources are limited by intrinsic linewidth, count rate, or experimental complexity. In this work, we investigate fibercoupled optical photons as a compact calibration tool for an Athena-like TES array. Optical pulses at 405 nm were generated with an acousto-optic modulator and delivered through an optical fiber onto a selected TES pixel inside a dilution refrigerator, via a dedicated cryogenic alignment interface. Externally triggered pulses were processed with an optimal-filter pipeline, including baseline subtraction, drift correction, and multi-Gaussian reconstruction of the pulse-height spectrum. The reconstructed spectra show resolved photon-number peaks consistent with the Poissonian statistics expected from an attenuated coherent source, reaching equivalent energies above 400 eV with a mean photon number exceeding 100 per pulse. The detector response was further tested for linearity by comparing the measured photon-number distributions against those predicted from the independently calibrated number of photons sent to the detector and a single, globally estimated detection efficiency, confirming Poissonian, linear behaviour across nearly two orders of magnitude in photon number. These results demonstrate that fiber-delivered optical photons can probe the few-eV to sub-keV response of Athena-like TES microcalorimeters, offering a practical and extensible framework for future low-energy calibration studies.
References in corpus (9)
- Quantum characterization of superconducting photon counters
- Performance of the SRON Ti/Au Transition Edge Sensor X-ray Calorimeters
- Detection of Low-Energy Electrons with Transition-Edge Sensors
- Developments on frequency domain multiplexing readout for large arrays of transition-edge sensor X-ray micro-calorimeters
- TiAu TES 3232 pixel array: uniformity, thermal crosstalk and performance at different X-ray energies
- Thermal crosstalk of X-ray transition-edge sensor micro-calorimeters under frequency domain multiplexing readout
- Mapping the Perseus Galaxy Cluster with XRISM: Gas Kinematic Features and their Implications for Turbulence
- Chemical composition and enrichment of the Centaurus cluster core seen by XRISM/Resolve
- Demonstration of MHz frequency domain multiplexing readout of 37 transition edge sensors for high-resolution x-ray imaging spectrometers