Speckle-based X-ray microtomography via preconditioned Wirtinger flow
arXiv:2503.20146 · doi:10.1038/s41377-025-02118-z
Abstract
Quantitative phase imaging has been extensively studied in X-ray microtomography to improve the sensitivity and specificity of measurements, especially for low atomic number materials. However, obtaining quantitative phase images typically requires additional measurements or assumptions, which significantly limits the practical applicability. Here, we present preconditioned Wirtinger flow (PWF): an assumption-free, single-shot quantitative X-ray phase imaging method. Accurate phase retrieval is demonstrated using a specialized gradient-based algorithm with an accurate physical model. Partial coherence of the source is taken into account, extending the potential applications to bench-top sources. Improved accuracy and spatial resolution over conventional speckle tracking methods are experimentally demonstrated. The various samples are explored to demonstrate the robustness and versatility of PWF.
References in corpus (8)
- Non-invasive real-time imaging through scattering layers and around corners via speckle correlations
- Phase Retrieval via Wirtinger Flow: Theory and Algorithms
- Single-Image Geometric-Flow X-Ray Speckle Tracking
- Near-field speckle-scanning-based x-ray imaging
- Single-shot x-ray speckle-based imaging of a single-material object
- Compensation of aberration and speckle noise in quantitative phase imaging using lateral shifting and spiral phase integration
- X-ray Multimodal Intrinsic-Speckle-Tracking
- Single-frame far-field diffractive imaging with randomized illumination