Impact of trace amounts of water on the stability of Micro-Pattern Gaseous Detectors measured in Ar-CO (90-10)
arXiv:2503.03012 · doi:10.1016/j.nima.2025.170912
Abstract
In this study, we investigate the influence of humidity on the performance of various non-resistive Micro Pattern Gaseous Detectors, such as GEM, Thick-GEM, and Micromegas, operated with \ArCOtwo gas mixture. The water content is introduced in a range of \SIrange[range-units=single]{0}{5000}{\ppmV}. It is observed that the presence of increased humidity does not significantly degrade any of the studied performance criteria. On the contrary, our measurements suggest an improvement in discharge stability with increasing humidity levels at the highest gains and fields. No significant difference is observed at the lower gains, indicating that humidity helps to reduce the rate of spurious discharges related to electrode defects or charging-up of the insulating layers. We conclude that adding a small amount of water to the gas mixture may be beneficial for the stable operation of an MPGD.
11 pages, 9 figures
References in corpus (5)
- The upgrade of the ALICE TPC with GEMs and continuous readout
- Quality Control of Mass-Produced GEM Detectors for the CMS GE1/1 Muon Upgrade
- The large inner Micromegas modules for the Atlas Muon Spectrometer Upgrade: construction, quality control and characterization
- Systematic investigation of critical charge limits in Thick GEMs
- Impact of the gas choice and the geometry on the breakdown limits in Micromegas detectors