Magnetic field tunable spectral response of kinetic inductance detectors
arXiv:2409.03356 · doi:10.1063/5.0231368
Abstract
We tune the onset of optical response in aluminium kinetic inductance detectors from a natural cutoff frequency of 90 GHz to 60 GHz by applying an external magnetic field. The change in spectral response is due to the decrease of the superconducting gap, from 90 GHz at zero magnetic field to 60 GHz at a magnetic field of around 3 mT. We characterize the variation of the superconducting gap, the detector frequency shift and the internal quality factor as a function of the applied field. In principle, the magnetic field tunable response could be used to make spectroscopic measurements. In practice, the internal quality factor behaves hysteretically with the magnetic field due to the presence of vortices in the thin superconducting film. We conclude by discussing possible solutions to achieve spectroscopy measurements using kinetic inductance detectors and magnetic field.
References in corpus (11)
- Microwave response of vortices in superconducting thin films of Re and Al
- Strongly disordered TiN and NbTiN s-wave superconductors probed by microwave electrodynamics
- A wide field-of-view low-resolution spectrometer at APEX: instrument design and science forecast
- The MKID Exoplanet Camera for Subaru SCExAO
- Electrodynamics of granular aluminum from superconductor to insulator: observation of collective superconducting modes
- Superconducting granular aluminum resonators resilient to magnetic fields up to 1 Tesla
- The Canfranc Axion Detection Experiment (CADEx): Search for axions at 90 GHz with Kinetic Inductance Detectors
- BULLKID: Monolithic array of particle absorbers sensed by Kinetic Inductance Detectors
- The non-equilibrium response of a superconductor to pair-breaking radiation measured over a broad frequency band
- Magnetic field dependence of the internal quality factor and noise performance of lumped-element kinetic inductance detectors
- Design and testing of Kinetic Inductance Detector package for the Terahertz Intensity Mapper