MNTES: Modeling Nonlinearity of TES detectors for Enhanced Cosmic Microwave Background measurements with LiteBIRD
arXiv:2406.19567 · doi:10.1117/12.3018503
Abstract
Traditional methods of converting electronic readout counts to optical power incident on Transition Edge Sensors (TES) for Cosmic Microwave Background (CMB) observations involve a linear approximation. For the upcoming LiteBIRD CMB satellite, strict nonlinearity requirements must be met to prevent contamination of the science band at 4f by the 2f signal, which arises from differential transmission or emissivity related to the half-wave plate's rotation rate fHWP. These constraints cannot be met using hardware solutions alone and therefore require a form of nonlinearity correction. We present MNTES, a novel physics-based, nonlinear calibration technique. This method leverages our physical understanding of the TES power balance equation, accounts for imperfect voltage bias by casting the bias network as its Thévenin equivalent, and can incorporate external information such as time-varying magnetic fields and focal plane temperature variations. The detector-specific parameters of MNTES will be measured during the ground calibration campaign prior to the LiteBIRD launch, yielding conversion functions that can take raw time-ordered data and output the reconstructed incident optical power. MNTES will allow us to achieve LiteBIRD's goal of measuring the primordial tensor fluctuation spectrum to δr < 0.001.
arXiv commentConference proceedings of SPIE 2024: Astronomical Telescopes and Instrumentation
References in corpus (10)
- Nine-Year Wilkinson Microwave Anisotropy Probe (WMAP) Observations: Final Maps and Results
- Planck 2018 results. I. Overview and the cosmological legacy of Planck
- Frequency Multiplexed SQUID Readout of Large Bolometer Arrays for Cosmic Microwave Background Measurements
- A Review of X-ray Microcalorimeters Based on Superconducting Transition Edge Sensors for Astrophysics and Particle Physics
- Planck 2013 results. III. LFI systematic uncertainties
- Improved Performance of TES Bolometers using Digital Feedback
- Probing Cosmic Inflation with the LiteBIRD Cosmic Microwave Background Polarization Survey
- Performance and characterization of the SPT-3G digital frequency-domain multiplexed readout system using an improved noise and crosstalk model
- Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers
- Modelling TES non-linearity induced by a rotating HWP in a CMB polarimeter