Systematic error mitigation for the PIXIE Fourier transform spectrometer
arXiv:2304.00091 · doi:10.1088/1475-7516/2023/07/057
Abstract
The Primordial Inflation Explorer (PIXIE) is an Explorer-class mission concept to measure the spectrum and polarization of the cosmic microwave background. Cosmological signals are small compared to the instantaneous instrument noise, requiring strict control of instrumental signals. The instrument design provides multiple levels of null operation, signal modulation, and signal differences, with only few-percent systematic error suppression required at each level. Jackknife tests based on discrete instrument symmetries provide an independent means to identify, model, and remove remaining instrumental signals. We use detailed time-ordered simulations, including realistic performance and tolerance parameters, to evaluate the instrument response to broad classes of systematic errors for both spectral distortions and polarization. The largest systematic errors contribute additional white noise at the few-percent level compared to the dominant photon noise. Coherent instrumental effects which do not integrate down are smaller still, and remain several orders of magnitude below the targeted cosmological signals.
arXiv comment37 pages including 23 figures. Matches published version
References in corpus (25)
- HEALPix -- a Framework for High Resolution Discretization, and Fast Analysis of Data Distributed on the Sphere
- Nine-Year Wilkinson Microwave Anisotropy Probe (WMAP) Observations: Cosmological Parameter Results
- 4-Year COBE DMR Cosmic Microwave Background Observations: Maps and Basic Results
- The Primordial Inflation Explorer (PIXIE): A Nulling Polarimeter for Cosmic Microwave Background Observations
- CMB-S4 Science Case, Reference Design, and Project Plan
- Planck intermediate results. XLVI. Reduction of large-scale systematic effects in HFI polarization maps and estimation of the reionization optical depth
- Planck 2018 results. III. High Frequency Instrument data processing and frequency maps
- Planck 2015 results. VIII. High Frequency Instrument data processing: Calibration and maps
- Benchmark Parameters for CMB Polarization Experiments
- Planck 2013 results. IX. HFI spectral response
- LiteBIRD: JAXA's new strategic L-class mission for all-sky surveys of cosmic microwave background polarization
- CMB Polarization Systematics Due to Beam Asymmetry: Impact on Inflationary Science
- Planck 2015 results. III. LFI systematic uncertainties
- Systematic errors in cosmic microwave background polarization measurements
- Planck 2013 results X. Energetic particle effects: characterization, removal, and simulation
- PICO: Probe of Inflation and Cosmic Origins
- The ARCADE 2 Instrument
- CMB Spectral Distortions: Status and Prospects
- Beam mismatch effects in Cosmic Microwave Background polarization measurements
- Systematic Errors in Cosmic Microwave Background Interferometry
- BeyondPlanck X. Bandpass and beam leakage corrections
- Calibration Method and Uncertainty for the Primordial Inflation Explorer (PIXIE)
- Systematic effects in polarizing Fourier transform spectrometers for cosmic microwave background observations
- Some sources of systematic errors on CMB polarized measurements with bolometers
- Time-ordered data simulation and map-making for the PIXIE Fourier transform spectrometer