Design, construction and commissioning of the PandaX-30T liquid xenon management system
arXiv:2301.06044 · doi:10.1088/1748-0221/18/05/P05028
Abstract
The PandaX-30T is a proposed next-generation experiment to study dark matter and neutrinos using a dual-phase time projection chamber with \textasciitilde30 tons of liquid xenon. An innovative xenon handling subsystem of the PandaX-30T, the First-X, is described in this paper. The First-X is developed to handle liquid xenon safely and efficiently, including liquefying and long-term storing xenon without losses or contamination, and transferring cryogenic liquid xenon between the storage module and the detector safely and effectively without venting out. The storage module of the First-X is five specially designed double-walled cylindrical vessels (Center Tanks) equipped with three heat exchangers each for pressure and temperature regulation. Each Center Tank is designed with a vacuum and multi-layer insulation and a maximum allowable working pressure of 7.1 MPa, allowing 6 tons of xenon to be stored at 165--178 K at 0.1--0.2 MPa in the liquid phase or up to 300 K and up to 6.95 MPa in the supercritical phase. High-pressure storage (\textgreater0.2 MPa) only occurs in case of long-term detector shutdown or lack of nitrogen, ensuring no-loss storage of 6 tons of xenon in the range 178--300 K. In this paper, the thermophysical performances of the First-X and innovative scenarios to conduct non-vented cryogen transportation were experimentally conducted and reported using liquid argon. The non-vented cryogenic liquid filling and pump-assisted cryogenic liquid recovery have been conducted with liquid argon at a mass flow rate of 1390 kg/h, corresponding to a xenon mass flow rate of 2140 kg/h. Compared with the PandaX-4T, the transportation of xenon between the detector and the storage module is conducted in the liquid phase rather than in the gaseous phase, and the filling rate and the recovery rate are increased by approximately 50 times and 30 times, respectively.
25 pages, 17 figures
References in corpus (13)
- Dark Matter Results From 54-Ton-Day Exposure of PandaX-II Experiment
- First Dark Matter Search Results from the LUX-ZEPLIN (LZ) Experiment
- Dark Matter Results from First 98.7-day Data of PandaX-II Experiment
- Dark Matter Search Results from the PandaX-4T Commissioning Run
- DARWIN: towards the ultimate dark matter detector
- Search for New Physics in Electronic Recoil Data from XENONnT
- The LUX-ZEPLIN (LZ) Experiment
- The China Jinping Underground Laboratory and its Early Science
- A Search for the Cosmic Ray Boosted Sub-GeV Dark Matter at the PandaX-II Experiment
- A Search for Light Fermionic Dark Matter Absorption on Electrons in PandaX-4T
- First search for the absorption of fermionic dark matter with the PandaX-4T experiment
- The Cryogenics and Xenon handling system for the PandaX-4T Experiment
- Design and construction of Xenoscope -- a full-scale vertical demonstrator for the DARWIN observatory
Cited by in corpus (5)
- Solar chameleons: Novel channels
- Supernova electron-neutrino interactions with xenon in the nEXO detector
- WIMP Dark Matter from a Natural Discrete Gauge Symmetry in the Standard Model
- Scattering meets absorption in dark matter detection
- Féeton ( Gauge Boson) Dark Matter Testable in Future Direct Detection Experiments