What surfaces in the operation of noble liquids dark matter detectors
arXiv:2212.12969 · doi:10.1088/1748-0221/18/07/C07011
Abstract
Electron and ion accumulation atop liquid can lead to formation of macroscopic charged hillocks and electrospraying, small signal suppression by charged crust. Design changes for large detectors are required.
12 pages, 9 figures. Submitted for publication at the preceding Light Detection in Noble Elements (LIDINE2022) conference
References in corpus (7)
- First Dark Matter Search Results from the LUX-ZEPLIN (LZ) Experiment
- A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
- The ZEPLIN-III dark matter detector: instrument design, manufacture and commissioning
- EXCESS workshop: Descriptions of rising low-energy spectra
- Investigation of background electron emission in the LUX detector
- Electron extraction efficiency study for dual-phase xenon dark matter experiments
- Detecting Low-Energy Interactions and the Effects of Energy Accumulation in Materials