Photometric recalibration of the SDSS Stripe 82 to a few milimagnitude precision with the stellar color regression method and Gaia EDR3
arXiv:2112.14956 · doi:10.3847/1538-4365/ac470d
Abstract
By combining spectroscopic data from the LAMOST DR7, SDSS DR12, and corrected photometric data from the Gaia EDR3, we apply the Stellar Color Regression (SCR; Yuan et al. 2015a) method to recalibrate the SDSS Stripe 82 standard stars catalog of Ivezić et al. (2007). With a total number of about 30,000 spectroscopically targeted stars, we have mapped out the relatively large and strongly correlated photometric zero-point errors present in the catalog, 2.5 per cent in the band and 1 per cent in the bands. Our study also confirms some small but significant magnitude dependence errors in the band for some charge-coupled devices. Various tests show that we have achieved an internal precision of about 5 mmag in the band and about 2 mmag in the bands, which is about 5 times better than previous results. We also apply the method to the latest version of the catalog (V4.2; Thanjavur et al. 2021), and find modest systematic calibration errors up to 1 per cent along the R.A. direction and smaller errors along the Dec. direction. The results demonstrate the power of the SCR method when combining spectroscopic data and Gaia photometry in breaking the 1 percent precision barrier of ground-based photometric surveys. Our work paves the way for the re-calibration of the whole SDSS photometric survey and has important implications for the calibration of future surveys. Future implementations and improvements of the SCR method under different situations are also discussed.
21 pages, 20 figures, 9 tables, ApJS in press
References in corpus (20)
- The Gaia mission
- The GALAH Survey: Scientific Motivation
- The SEGUE Stellar Parameter Pipeline. I. Description and Initial Validation Tests
- APOGEE Data and Spectral Analysis from SDSS Data Release 16: Seven Years of Observations Including First Results from APOGEE-South
- SDSS Standard Star Catalog for Stripe 82: the Dawn of Industrial 1% Optical Photometry
- The SEGUE Stellar Parameter Pipeline. II. Validation with Galactic Globular and Open Clusters
- The LAMOST Stellar Parameter Pipeline at Peking University --- LSP3
- Forward Global Photometric Calibration of the Dark Energy Survey
- Toward 1% Photometry: End-to-end Calibration of Astronomical Telescopes and Detectors
- Estimating stellar atmospheric parameters, absolute magnitudes and elemental abundances from the LAMOST spectra with Kernel-based Principal Component Analysis
- Milky Way Tomography with the SkyMapper Southern Survey. II. Photometric Re-calibration of SMSS DR2
- Stellar color regression: a spectroscopy based method for color calibration to a few mmag accuracy and the recalibration of Stripe 82
- Stellar loci I. Metallicity dependence and intrinsic widths
- Correction to the photometric colors of Gaia Early Data Release 3
- Photometric Cross-Calibration of the SDSS Stripe 82 Standard Stars catalogue with Gaia EDR3, and Comparison with Pan-STARRS1, DES, CFIS and GALEX catalogues
- Stellar loci III: Photometric metallicities for half million FGK stars of Stripe 82
- Correction to the photometric magnitudes of the Gaia Early Data Release 3
- Correction to the photometric colors of the Gaia Data Release 2 with the stellar color regression method
- Dust in the outskirts of M31 and M33
- Determining thermal dust emission from Planck HFI data using a sparse, parametric technique
Cited by in corpus (3)
- J-PLUS: Stellar Parameters, C, N, Mg, Ca and [α/Fe] Abundances for Two Million Stars from DR1
- Photometric calibration of the Stellar Abundance and Galactic Evolution Survey (SAGES): Nanshan One-meter Wide-field Telescope g, r, and i band imaging data
- The miniJPAS survey: stellar atmospheric parameters from 56 optical filters