A ruthenium oxide thermometer for dilution refrigerators operating down to 5 mK
arXiv:2110.03788 · doi:10.1016/j.cryogenics.2021.103367
Abstract
At the lowest temperatures achieved in dilution refrigerators, ruthenium oxide resistance thermometers often saturate and therefore lose their sensitivity. In an effort to extend the range of such temperature sensors, we built a thermometer which maintains sensitivity to 5~mK. A key component of this thermometer is an in situ radio frequency filter which is based on a modern rf absorption material. We show that the use of such a filter is only effective when it is encased in the same rf-tight enclosure as the ruthenium oxide sensor. Our design delivers an attenuation level that is necessary to mitigate the effects of parasitic heating of a fraction of pW present in our circuit. Furthermore, we show that the likely origin of this parasitic heating is the black body radiation present within the experimental space of the refrigerator. We found that the equilibration time of the thermometer increases rapidly as the temperature is lowered; below 5~mK this thermometer becomes impractical because of the prohibitively long equilibration times.
References in corpus (13)
- Exact Quantization of Even-Denominator Fractional Quantum Hall State at =5/2 Landau Level Filling Factor
- Wavefunctionology: The Special Structure of Certain Fractional Quantum Hall Wavefunctions
- Thirty Years of Composite Fermions and Beyond
- GaAs Quantum Dot Thermometry Using Direct Transport and Charge Sensing
- Integrated Electronic Transport and Thermometry at milliKelvin Temperatures and in Strong Magnetic Fields
- Progress in cooling nanoelectronic devices to ultra-low temperatures
- Silver-Epoxy Microwave Filters and Thermalizers for Millikelvin Experiments
- 500 microkelvin nanoelectronics
- Impedance-matched low-pass stripline filters
- Metallic Coulomb Blockade Thermometry down to 10 mK and below
- Magetoresistance of RuO_2-based resistance thermometers below 0.3 K
- Current Sensing Noise Thermometry: A fast practical solution to low temperature measurement
- A new type of carbon resistance thermometer with excellent thermal contact at millikelvin temperatures
Cited by in corpus (5)
- Interfering Josephson diode effect in Ta2Pd3Te5 asymmetric edge interferometer
- Ta2Pd3Te5 topological thermometer
- Effectiveness of Some 0 dB Cryogenic Microwave Attenuators as Thermal Heatsinks
- Fermi-liquid behavior and characteristic temperature-dependent susceptibility in clean RuO crystal
- Effects of the thin-film thickness on superconducting NbTi microwave resonators for on-chip cryogenic thermometry