paper

Development of high-rate capable and ultra-low mass Resistive Plate Chamber with Diamond-Like Carbon

arXiv:2109.13525 · doi:10.1088/1742-6596/2374/1/012143

Abstract

A new type of resistive plate chamber (RPC) is under development using thin-film resistive electrodes based on diamond-like carbon (DLC). Planned to be put on the path of high-intensity low-momentum muon beam of the MEG II experiment, this detector is required to be high-rate capable and ultra-low mass. Using a prototype detector with 2 cm 2 cm size and 0.1 % material budget, performance studies were conducted for MIP detection efficiency, timing resolution and high rate capability in low-momentum muon beam. In this paper, the measured performance is presented including the result with low-momentum muon beam at rate up to 1 . Based on the result, the expected performance of the full-scale detector in the MEG~II experiment is also discussed.

5 pages, 8 figures. Contribution to the International Conference on Technology and Instrumentation in Particle Physics (TIPP 2021), May 24-28 2021. Submitted to Journal of Physics: Conference Series

Cited by in corpus (1)