Automated crystal orientation mapping by precession electron diffraction assisted four-dimensional scanning transmission electron microscopy (4D-STEM) using a scintillator based CMOS detector
arXiv:2102.09711 · doi:10.1017/S1431927621012538
Abstract
The recent development of electron sensitive and pixelated detectors has attracted the use of four-dimensional scanning transmission electron microscopy (4D-STEM). Here, we present a precession electron diffraction assisted 4D-STEM technique for automated orientation mapping using diffraction spot patterns directly captured by an in-column scintillator based complementary metal-oxide-semiconductor (CMOS) detector. We compare the results to a conventional approach, which utilizes a fluorescent screen filmed by an external CCD camera. The high dynamic range and signal-to-noise characteristics of the detector largely improve the image quality of the diffraction patterns, especially the visibility of diffraction spots at high scattering angles. In the orientation maps reconstructed via the template matching process, the CMOS data yields a significant reduction of false indexing and higher reliability compared to the conventional approach. The angular resolution of misorientation measurement could also be improved by masking reflections close to the direct beam. This is because the orientation sensitive, weak and small diffraction spots at high scattering angle are more significant. The results show that fine details such as nanograins, nanotwins and sub-grain boundaries can be resolved with a sub-degree angular resolution which is comparable to orientation mapping using Kikuchi diffraction patterns.
References in corpus (5)
- High Dynamic Range Pixel Array Detector for Scanning Transmission Electron Microscopy
- Fast Pixelated Detectors in Scanning Transmission Electron Microscopy. Part I: Data Acquisition, Live Processing and Storage
- Fast Pixelated Detectors in Scanning Transmission Electron Microscopy. Part II: Post Acquisition Data Processing, Visualisation, and Structural Characterisation
- On the depth resolution of transmission Kikuchi diffraction (TKD) analysis
- Using the Medipix3 detector for direct electron imaging in the range 60keV to 200keV in electron microscopy
Cited by in corpus (5)
- Automated Crystal Orientation Mapping in py4DSTEM using Sparse Correlation Matching
- Atomic motifs govern the decoration of grain boundaries by interstitial solutes
- Effect of Pore Formation on Redox-Driven Phase Transformation
- Improved ACOM pattern matching in 4D STEM through adaptive sub pixel peak detection and image reconstruction
- Ultra-fast Digital DPC Yielding High Spatio-Temporal Resolution for Low-Dose Phase Characterisation