Performance of the diamond-based beam-loss monitor system of Belle II
arXiv:2102.04800 · doi:10.1016/j.nima.2021.165157
Abstract
We designed, constructed and have been operating a system based on single-crystal synthetic diamond sensors, to monitor the beam losses at the interaction region of the SuperKEKB asymmetric-energy electron-positron collider. The system records the radiation dose-rates in positions close to the inner detectors of the Belle II experiment, and protects both the detector and accelerator components against destructive beam losses, by participating in the beam-abort system. It also provides complementary information for the dedicated studies of beam-related backgrounds. We describe the performance of the system during the commissioning of the accelerator and during the first physics data taking.
References in corpus (1)
Cited by in corpus (10)
- The Design, Construction, Operation and Performance of the Belle II Silicon Vertex Detector
- Measured and projected beam backgrounds in the Belle II experiment at the SuperKEKB collider
- Calibration of diamond detectors for dosimetry in beam-loss monitoring
- Improved simulation of beam backgrounds and collimation at SuperKEKB
- The Silicon Vertex Detector of the Belle II Experiment
- Development and Implementation of Advanced Beam Diagnostic and Abort Systems in SuperKEKB
- A neural network for beam background decomposition in Belle II at SuperKEKB
- Simulation of the response of a diamond-based radiation detector to ultra-short and intense high-energy electron pulses
- The Silicon Vertex Detector of the Belle II Experiment
- Charge-Carrier Mobility in Diamond: Review, Data Compilation, and Modelling for Detector Simulations