Advances in secondary ion mass spectroscopy
arXiv:2012.05956 · doi:10.1116/6.0000848
Abstract
Accurate SIMS measurement of nitrogen in niobium relies on the use of closely equivalent standards, made by ion implantation, to convert nitrogen signal intensity to nitrogen content by determination of relative sensitivity factors (RSF). Accurate RSF values for ppm-range nitrogen contents are increasingly critical, as more precision is sought in processes for next-generation superconducting radio-frequency (SRF) accelerator cavities. Factors influencing RSF value measurements were investigated with the aim of reliably attaining better than 10% accuracy in N concentrations at various depths into the bulk. This has been accomplished for materials typical of SRF cavities at the cost of great attention to all aspects.
Cited by in corpus (3)
- Niobium's intrinsic coherence length and penetration depth revisited using low-energy muon spin spectroscopy and secondary-ion mass spectrometry
- Search for inhomogeneous Meissner screening in Nb induced by low-temperature surface treatments
- RF surface resistance tuning of superconducting niobium via thermal diffusion of native oxide