Ternary Quarter Wavelength Coatings for Gravitational Wave Detector Mirrors: Design Optimization via Exhaustive Search
arXiv:2012.02146 · doi:10.1103/PhysRevResearch.3.023172
Abstract
Multimaterial optical coatings are a promising viable option to meet the challenging requirements (in terms of transmittance, absorbance and thermal noise) of next generation gravitational wave detector mirrors. In this paper we focus on ternary coatings consisting of quarter-wavelength thick layers, where a third material (H') is added to the two presently in use, namely Silica (L) and Titania-doped Tantala (H), featuring higher dielectric contrast (against Silica), and lower thermal noise (compared to Titania-doped Tantala), but higher optical losses. We seek the optimal material sequences, featuring minimal thermal (Brownian) noise under prescribed transmittance and absorbance constraints, by exhaustive simulation over all possible configurations, for different values (in a meaningful range) of the optical density and extinction coefficient of the third material. In all cases studied, the optimal designs consist of a stack of (H'|L) doublets topped by a stack of (H|L) doublets, confirming previous heuristic assumptions, and the achievable coating noise power spectral density reduction factor is \sim 0.5. The robustness of the found optimal designs against layer thickness deposition errors and uncertainties and/or fluctuations in the optical losses of the third material is also investigated. Possible margins for further thermal noise reduction by layer thickness optimization, and strategies to implement it, are discussed.
arXiv comment(twocolum style) 13 pages, 8 figures, 4 table (updated version 5) Appearing on Physical Review Research
References in corpus (16)
- Advanced Virgo: a 2nd generation interferometric gravitational wave detector
- Advanced LIGO
- KAGRA: 2.5 Generation Interferometric Gravitational Wave Detector
- The Sensitivity of the Advanced LIGO Detectors at the Beginning of Gravitational Wave Astronomy
- Titania-doped tantala/silica coatings for gravitational-wave detection
- A Cryogenic Silicon Interferometer for Gravitational-wave Detection
- Brownian Thermal Noise in Multilayer Coated Mirrors
- Measurement of Thermal Noise in Multilayer Coatings with Optimized Layer Thickness
- Multi-Material Coatings with Reduced Thermal Noise
- Measurements of a low temperature mechanical dissipation peak in a single layer of Ta2O5 doped with TiO2
- Thermal Noise Reduction and Absorption Optimisation via Multi-Material Coatings
- Progress in the measurement and reduction of thermal noise in optical coatings for gravitational-wave detectors
- Effect of interference on thermal noise and coating optimization in dielectric mirrors
- Building blocks for future detectors: Silicon test masses and 1550 nm laser light
- Minimum Noise Optical Coatings for Interferometric Detectors of Gravitational Waves
- On the performance limits of coatings for gravitational wave detectors made of alternating layers of two materials
Cited by in corpus (5)
- Development of ion-beam sputtered silicon nitride thin films for low-noise mirror coatings of gravitational-wave detectors
- Thermorefringent noise in crystalline optical materials
- Optimal Design of Coatings for Mirrors of Gravitational Wave Detectors: Analytic Turbo Solution via Herpin Equivalent Layers
- Thermal Noise Reduction in Ternary Optical Coatings: From Ti::GeO-Based Ternary Systems to High Index Materials
- Comparative Analysis of Thermal Models for Test Masses in Next-Generation Gravitational Wave Interferometers