Low Gain Avalanche Detectors for the HADES reaction time (T) detector upgrade
arXiv:2005.12965 · doi:10.1140/epja/s10050-020-00186-w
Abstract
Low Gain Avalanche Detector (LGAD) technology has been used to design and construct prototypes of time-zero detector for experiments utilizing proton and pion beams with High Acceptance Di-Electron Spectrometer (HADES) at GSI Darmstadt, Germany. LGAD properties have been studied with proton beams at the COoler SYnchrotron (COSY) facility in Jülich, Germany. We have demonstrated that systems based on a prototype LGAD operated at room temperature and equipped with leading-edge discriminators reach a time precision below 50 ps. The application in the HADES, experimental conditions, as well as the test results obtained with proton beams are presented.
arXiv commentpublished in Eur. Phys. J. A 56, 183 (2020)
References in corpus (5)
- The High-Acceptance Dielectron Spectrometer HADES
- Beam test results of a 16 ps timing system based on ultra-fast silicon detectors
- First FBK Production of 50m Ultra-Fast Silicon Detectors
- Radiation Hardness of Thin Low Gain Avalanche Detectors
- Diamonds as timing detectors for MIP: The HADES proton-beam monitor and start detectors