Abstract
A high-precision measurement of the CsXe ground-to-ground-state electron-capture -value was performed using the ISOLTRAP mass spectrometer at ISOLDE/CERN. The novel PI-ICR technique allowed to reach a relative mass precision of . A mass resolving power exceeding was obtained in only s trapping time. Allowed electron-capture transitions with sub-keV or lower decay energies are of high interest for the direct determination of the mass. The new measurement improves the uncertainty on the ground-to-ground-state -value by a factor 25 precluding the CsXe pair as a feasible candidate for the direct determination of the mass.
arXiv commentAccepted by Hyperfine Interactions. TCP18 conference proceeding. 10 pages, 4 figures, 1 table
References in corpus (8)
- ROOT - A C++ Framework for Petabyte Data Storage, Statistical Analysis and Visualization
- High-precision measurement of the atomic mass of the electron
- A linear radiofrequency ion trap for accumulation, bunching, and emittance improvement of radioactive ion beams
- Separated Oscillatory Fields for High-Precision Penning Trap Mass Spectrometry
- Direct Measurement of the Mass Difference of Ho163 and Dy163 Solves the Q-Value Puzzle for the Neutrino Mass Determination
- Precision Mass Measurement of Cr: Nuclear Collectivity towards the \emph{N}=40 Island of Inversion
- Q-Value and Half-Lives for the Double-Beta-Decay Nuclide 110Pd
- Direct determination of the atomic mass difference of Re187 and Os187 for neutrino physics and cosmochronology
Cited by in corpus (12)
- Neutrinoless Double-Electron Capture
- Gaussian mixture model clustering algorithms for the analysis of high-precision mass measurements
- First glimpse of the shell closure below from masses of neutron-rich cadmium isotopes and isomers
- Direct measurement of the mass difference of As-Ge rules out As as a promising -decay candidate to determine the neutrino mass
- Updated evaluation of potential ultra-low Q value -decay candidates
- Precise Q value measurements of Ag and Cd with the Canadian Penning trap for evaluation of potential ultra-low Q value -decays
- decay -value measurement of Cs and its implications to neutrino studies
- Identification of a potential ultra-low Q value electron capture decay branch in Se via a precise Penning trap measurement of the mass of As
- Analysis methods and code for very high-precision mass measurements of unstable isotopes
- High-precision measurements of the atomic mass and electron-capture decay value of Tc
- High-precision direct decay energy measurements of the electron-capture decay of Tc
- Ultra-low value for the allowed decay of Ag confirmed via mass measurements