Probing low-mass WIMP candidates of dark matter with tetrafluoroethane superheated liquid detectors
arXiv:1905.04706 · doi:10.1103/PhysRevD.101.103005
Abstract
Probing low mass (sub-GeV -- few GeV) Weakly Interacting Massive Particle (WIMP) candidates of dark matter through WIMP-induced nuclear recoils in direct detection experiments requires use of detector materials consisting of low mass target nuclei and low threshold energy. Here we explore the potential of superheated liquid detectors (SLD) with a hydrogen containing liquid, namely, tetrafluoroethane (CHF) (b.p.~C), as the target material for probing low mass WIMPs. It is found that few-keV level recoil energy thresholds possible for bubble nucleation by WIMP-induced C and F recoils in CHF SLDs operated at atmospheric pressure and gamma-ray insensitive temperatures of C have the potential to allow WIMPs in the few-GeV mass range to be probed at a WIMP-nucleon spin-independent cross section sensitivity levels (90% C.L.) better than pb at WIMP masses down to 4 GeV with a total exposure of 1000 kg.day, provided that the ``thermodynamic efficiency" that determines the bubble nucleation thresholds for the recoiling nuclei in CHF is 50% or higher. Sensitivity to sub-GeV WIMP masses generally requires the detector to be sensitive to the WIMP-induced H recoils, which in turn requires the detector to be operated at temperatures C and close to 100%. At such relatively high temperatures (at atmospheric pressure), however, the detector would be sensitive to background gamma rays.
arXiv commentMajor revisions: title and abstract slightly changed; method of estimating the bubble nucleation thresholds reformulated; main qualitative conclusions remain unchanged; Latex 27 pages, 9 figures; new references added; matches version accepted for publication in PRD
References in corpus (28)
- Particle Dark Matter: Evidence, Candidates and Constraints
- Supersymmetric Dark Matter
- First results from DAMA/LIBRA and the combined results with DAMA/NaI
- Dark Matter Results From 54-Ton-Day Exposure of PandaX-II Experiment
- First Dark Matter Search Results from the XENON1T Experiment
- New results from DAMA/LIBRA
- The RAVE Survey: Constraining the Local Galactic Escape Speed
- WIMP dark matter candidates and searches - current status and future prospects
- Final model independent result of DAMA/LIBRA-phase1
- The Local Dark Matter Density
- Low-Mass Dark Matter Search with the DarkSide-50 Experiment
- Dark matter direct-detection experiments
- Annual Modulation of Dark Matter: A Review
- Results on light dark matter particles with a low-threshold CRESST-II detector
- Dark Matter Search Results from the Complete Exposure of the PICO-60 CF Bubble Chamber
- Dark Matter Search Results from the PICO-60 CF Bubble Chamber
- Limits on spin-dependent WIMP-nucleon cross section obtained from the complete LUX exposure
- Low-Mass Dark Matter Search with CDMSlite
- First results from the NEWS-G direct dark matter search experiment at the LSM
- Improved Limits on Spin-Dependent WIMP-Proton Interactions from a Two Liter CFI Bubble Chamber
- Limits on Light Weakly Interacting Massive Particles from the First 102.8 kg day Data of the CDEX-10 Experiment
- Dark Matter Search Results from the PICO-60 CFI Bubble Chamber
- Final Results of the PICASSO Dark Matter Search Experiment
- Dark Matter implications of DAMA/LIBRA-phase2 results
- The SIMPLE Phase II Dark Matter Search
- Data-Driven Modeling of Electron Recoil Nucleation in PICO CF Bubble Chambers
- Characterization of R-134A superheated droplet detector for neutron detection
- MOSCAB: A geyser-concept bubble chamber to be used in a dark matter search