A Light Calibration System for the ProtoDUNE-DP Detector
arXiv:1902.07127 · doi:10.1088/1748-0221/14/04/T04001
Abstract
A LED-based fiber calibration system for the ProtoDUNE-Dual Phase (DP) photon detection system (PDS) has been designed and validated. ProtoDUNE-DP is a 6x6x6 m3 liquid argon time-projection-chamber currently being installed at the Neutrino Platform at CERN. The PDS is based on 36 8-inch photomultiplier tubes (PMTs) and will allow triggering on cosmic rays. The system serves as prototype for the PDS of the final DUNE DP far detector in which the PDS also has the function to allow the 3D event reconstruction on non-beam physics. For this purpose an equalized PMT response is desirable to allow using the same threshold definition for all PMT groups, simplifying the determination of the trigger efficiency. The light calibration system described in this paper is developed to provide this and to monitor the PMT performance in-situ.
15 pages, 5 figures
References in corpus (7)
- Absorption of Scintillation Light in a 100 Liquid Xenon Ray Detector and Expected Detector Performance
- Characterization of large area photomutipliers under low magnetic fields: design and performances of the magnetic shielding for the Double Chooz neutrino experiment
- The MINOS Light Injection Calibration System
- A 4 tonne demonstrator for large-scale dual-phase liquid argon time projection chambers
- Cryogenic R5912-20Mod Photomultiplier Tube Characterization for the ProtoDUNE Dual Phase Detector
- The Photomultiplier Tube Calibration System of the MicroBooNE Experiment
- Photon detection system for ProtoDUNE dual phase