Uncertainties in the Static Dielectric Constants computed from Molecular Dynamics Simulations
arXiv:1901.02127 · doi:10.1016/j.molliq.2019.111021
Abstract
In this work, the uncertainties in the dielectric constants of polar liquids, computed using molecular dynamics (MD) simulations, are compared for two different calculations schemes. Expressions of the uncertainty are derived for the external field method, and compared with those of the fluctuation method. Significant differences on their the system size dependence were found. In addition, alternative calculation procedures are proposed. The individual contributions of different parts of the system to the electric susceptibility, and their corresponding uncertainties, are also studied. Additionally, the effects of the sampling frequency on the uncertainties are analyzed. MD simulations of pure liquid water (SPC/E) at 298.15 K and 1 bar were performed in order to corroborate the obtained results. In such conditions, the best estimate of the dielectric constant obtained in this study is 70.460.31.
arXiv commentminor errors correction, many clarifications added
References in corpus (6)
- Canonical sampling through velocity-rescaling
- The NumPy array: a structure for efficient numerical computation
- Models of dielectric relaxation based on completely monotone functions
- On the accurate calculation of the dielectric constant and the diffusion coefficient from molecular dynamics simulations: the case of SPC/E water
- Boundary conditions in local electrostatics algorithms
- Uncertainties in permittivities computed from molecular dynamics simulations and temperature correction of dielectric properties of condensed polar systems