Sources of heading error in optically pumped magnetometers operated at Earth's magnetic field
arXiv:1809.00627 · doi:10.1103/PhysRevA.99.013420
Abstract
When optically pumped magnetometers are aimed for the use in Earth's magnetic field, the orientation of the sensor to the field direction is of special importance to achieve accurate measurement result. Measurement errors and inaccuracies related to the heading of the sensor can be an even more severe problem in the case of special operational configurations, such as for example the use of strong off-resonant pumping. We systematically study the main contributions to the heading error in systems that promise high magnetic field resolutions at Earth's magnetic field strengths, namely the non-linear Zeeman splitting and the orientation dependent light shift. The good correspondence of our theoretical analysis to experimental data demonstrates that both of these effects are related to a heading dependent modification of the interaction between the laser light and the dipole moment of the atoms. Also, our results promise a compensation of both effects using a combination of clockwise and counter clockwise circular polarization.
arXiv comment11 pages, 11 figures
References in corpus (13)
- Resonant nonlinear magneto-optical effects in atoms
- Dynamical polarizability of atoms in arbitrary light fields: general theory and application to cesium
- A 20-Channel Magnetoencephalography System Based on Optically Pumped Magnetometers
- Isotropic magnetometry with simultaneous excitation of orientation and alignment CPT resonances
- Synchronous Optical Pumping of Quantum Revival Beats for Atomic Magnetometery
- A large sample study of spin relaxation and magnetometric sensitivity of paraffin-coated Cs vapor cells
- Suppression of nonlinear Zeeman effect and heading error in earth-field-range alkali-vapor magnetometers
- Cancellation of nonlinear Zeeman shifts with light shifts
- Dressed-state amplification by a superconducting qubit
- Observation of vector and tensor light shifts in 87Rb using near-resonant, stimulated Raman spectroscopy
- Orientational Effects on the Amplitude and Phase of Polarimeter Signals in Double Resonance Atomic Magnetometry
- High-precision control of static magnetic field magnitude, orientation, and gradient using optically pumped vapour cell magnetometry
- Sensitive optical atomic magnetometer based on nonlinear magneto-optical rotation
Cited by in corpus (7)
- How to build a magnetometer with thermal atomic vapor: A tutorial
- Integrated optically pumped magnetometer for measurements within Earth's magnetic field
- Heading errors in all-optical alkali-vapor magnetometers in geomagnetic fields
- Heading-error-free optical atomic magnetometry in the Earth-field range
- Performance analysis of an optically pumped magnetometer in Earth's magnetic field
- Correcting heading errors in optically pumped magnetometers through microwave interrogation
- Investigating the hyperfine systematic error and relative phase in low spin-polarization alkali FID magnetometers