We have manufactured more than 250 nominally identical paraffin-coated Cs vapor cells (30 mm diameter bulbs) for multi-channel atomic magnetometer applications. We describe our dedicated cell characterization apparatus. For each cell we have determined the intrinsic longitudinal, $\sGamma{01}$, and transverse, $\sGamma{02}$, relaxation rates. Our best cell shows $\sGamma{01}/2π\approx 0.5 Hz, and $\sGamma{02}/2π\approx 2 Hz. We find a strong correlation of both relaxation rates which we explain in terms of reservoir and spin exchange relaxation. For each cell we have determined the optimal combination of rf and laser powers which yield the highest sensitivity to magnetic field changes. Out of all produced cells, 90% are found to have magnetometric sensitivities in the range of 9 to 30 fTHz. Noise analysis shows that the magnetometers operated with such cells have a sensitivity close to the fundamental photon shot noise limit.
References in corpus (9)
- Optical Magnetometry
- Resonant nonlinear magneto-optical effects in atoms
- Spin squeezing of atomic ensembles via nuclear-electronic spin entanglement
- Investigation of microwave transitions and nonlinear magneto-optical rotation in anti-relaxation-coated cells
- Theory of double resonance magnetometers based on atomic alignment
- Slow light in paraffin-coated Rb vapor cells
- Optimization and performance of an optical cardio-magnetometer
- Experimental study of laser detected magnetic resonance based on atomic alignment
- Sensitivity of double resonance alignment magnetometers
Cited by in corpus (17)
- Sub-femtotesla scalar atomic magnetometer using multipass cells
- A room temperature 19-channel magnetic field mapping device for cardiac signals
- Global Network of Optical Magnetometers for Exotic (GNOME): Physics Novel scheme for exotic physics searches
- How to build a magnetometer with thermal atomic vapor: A tutorial
- Atomic magnetic resonance induced by amplitude-, frequency-, or polarization-modulated light
- Characterization of the Global Network of Optical Magnetometers to search for Exotic Physics (GNOME)
- Investigation of Anti-Relaxation Coatings for Alkali-Metal Vapor Cells Using Surface Science Techniques
- Sources of heading error in optically pumped magnetometers operated at Earth's magnetic field
- Vector Magnetometry Exploiting Phase-Geometry Effects in a Double-Resonance Alignment Magnetometer
- A highly stable atomic vector magnetometer based on free spin precession
- Optically Pumped Cs Magnetometers Enabling a High-Sensitivity Search for the Neutron Electric Dipole Moment
- Cavity enhanced atomic magnetometry
- Orientational Effects on the Amplitude and Phase of Polarimeter Signals in Double Resonance Atomic Magnetometry
- Design and performance of an absolute He/Cs magnetometer
- High-precision control of static magnetic field magnitude, orientation, and gradient using optically pumped vapour cell magnetometry
- Optical Magnetometry based Current Source
- Relaxation of Cs atomic polarization at surface coatings characterized by X-ray photoelectron spectroscopy