Development of new radon monitoring systems in the Kamioka mine
arXiv:1807.11142 · doi:10.1093/ptep/pty091
Abstract
Radioactivity from radon is a major threat for high-precision low energy physics experiments like the ones in the Kamioka Mine. We developed a new high sensitive radon monitoring system and conducted systematic radon concentration measurements for the first time in Kamioka. The system consists of portable radon detectors with a capacity of 1 L and new electronics based on Raspberry Pi. These radon detectors measure the radon in air with electro-static collection and a PIN photodiode. We measured the absolute humidity dependence of the 1-L radon detector for air to be . The background level of the 1-L radon detector is (stat.) count/day. This corresponds to a detection limit of Bq/m in a one-day measurement. Data was collected for a period of more than one year with twenty one 1-L radon detectors in the Kamioka mine. They indicate seasonal and day-night variations in radon concentration within the mine. These results also allow us to confirm the stability of the new Raspberry Pi electronics.
arXiv comment21 pages, 22 figures, to be published in PTEP Erratum on 2019/03/06: Figures 15 and 16 were corrected, this doesn't change our conclusions
References in corpus (4)
Cited by in corpus (4)
- Solar neutrino measurements using the full data period of Super-Kamiokande-IV
- Sensitivity of Super-Kamiokande with Gadolinium to Low Energy Anti-neutrinos from Pre-supernova Emission
- Cosmic Ray Muons in Laboratories Deep Underground
- Study of radon removal performance of silver-ion exchanged zeolite from air for underground experiments