On-sky compensation of non-common path aberrations with the ZELDA wavefront sensor in VLT/SPHERE
arXiv:1806.06158
Abstract
Circumstellar environments are now routinely observed by dedicated high-contrast imagers on large, ground-based observatories. These facilities combine extreme adaptive optics and coronagraphy to achieve unprecedented sensitivities for exoplanet detection and spectral characterization. However, non-common path aberrations (NCPA) in these coronagraphic systems represent a critical limitation for the detection of giant planets with a contrast lower than a few at very small separations (0.3) from their host star. In 2013 we proposed ZELDA, a Zernike wavefront sensor to measure these residual quasi-static phase aberrations and a prototype was installed in SPHERE, the exoplanet imager for the VLT. In 2016, we demonstrated the ability of our sensor to provide a nanometric calibration and compensation for these aberrations on an internal source in the instrument, resulting in a contrast gain of 10 at 0.2 in coronagraphic images. However, initial on-sky tests in 2017 did not show a tangible gain in contrast when calibrating the NCPA internally and then applying the correction on sky. In this communication, we present recent on-sky measurements to demonstrate the potential of our sensor for the NCPA compensation during observations and quantify the contrast gain in coronagraphic data.
arXiv comment9 pages, 4 figures. Proceeding of the SPIE Astronomical Telescopes + Instrumentation Conference, 10 - 15 June 2018
References in corpus (6)
- The Gemini Planet Imager: First Light
- Calibration of quasi-static aberrations in exoplanet direct-imaging instruments with a Zernike phase-mask sensor
- Calibration and Pre-Compensation of Non-Common Path Aberrations for extreme Adaptive Optics
- High-contrast imaging of Sirius~A with VLT/SPHERE: Looking for giant planets down to one astronomical unit
- Near-Infrared Detection and Characterization of the Exoplanet HD 95086 b with the Gemini Planet Imager