Absolute spectroscopy near 7.8 μm with a comb-locked extended-cavity quantum-cascade-laser
arXiv:1708.00500 · doi:10.1038/s41598-018-19188-2
Abstract
We report the first experimental demonstration of frequency-locking of an extended-cavity quantum-cascade-laser (EC-QCL) to a near-infrared frequency comb. The locking scheme is applied to carry out absolute spectroscopy of N2O lines near 7.87 μm with an accuracy of ~60 kHz. Thanks to a single mode operation over more than 100 cm^{-1}, the comb-locked EC-QCL shows great potential for the accurate retrieval of line center frequencies in a spectral region that is currently outside the reach of broadly tunable cw sources, either based on difference frequency generation or optical parametric oscillation. The approach described here can be straightforwardly extended up to 12 μm, which is the current wavelength limit for commercial cw EC-QCLs.
4 pages, 3 figures
Cited by in corpus (6)
- QCL-based frequency metrology from the mid-infrared to the THz range: a review
- High-precision methanol spectroscopy with a widely tunable SI-traceable frequency-comb-based mid-infrared QCL
- A mid-infrared dual-comb spectrometer in step-sweep mode for high-resolution molecular spectroscopy
- Optical Frequency Comb Fourier Transform Spectroscopy of NO at 7.8 μm
- Bending modes metrology in the 14-15 m region
- Near-to mid-IR spectral purity transfer with a tunable frequency comb: methanol frequency metrology over a record frequency span