Nonlinearity and pixel shifting effects in HXRG infrared detectors
arXiv:1703.08205 · doi:10.1088/1748-0221/12/04/C04009
Abstract
We study the nonlinearity (NL) in the conversion from charge to voltage in infrared detectors (HXRG) for use in precision astronomy. We present laboratory measurements of the NL function of a H2RG detector and discuss the accuracy to which it would need to be calibrated in future space missions to perform cosmological measurements through the weak gravitational lensing technique. In addition, we present an analysis of archival data from the infrared H1RG detector of the Wide Field Camera 3 in the Hubble Space Telescope that provides evidence consistent with the existence of a sensor effect analogous to the brighter-fatter effect found in Charge-Coupled Devices. We propose a model in which this effect could be understood as shifts in the effective pixel boundaries, and discuss prospects of laboratory measurements to fully characterize this effect.
arXiv commentAccepted for publication in the Journal of Instrumentation (JINST). Part of "Precision Astronomy with Fully Depleted CCDs" (Dec 1-2, 2016), Brookhaven National Laboratory, Upton, NY, USA
References in corpus (11)
- Systematic Errors in Future Weak Lensing Surveys: Requirements and Prospects for Self-Calibration
- Origins of weak lensing systematics, and requirements on future instrumentation (or knowledge of instrumentation)
- Systematic Bias in Cosmic Shear: Beyond the Fisher Matrix
- The brighter-fatter effect and pixel correlations in CCD sensors
- Defining a weak lensing experiment in space
- Characterization and correction of charge-induced pixel shifts in DECam
- Evidence for self-interaction of charge distribution in charge-coupled devices
- The Impact of Interpixel Capacitance in CMOS Detectors on PSF shapes and Implications for WFIRST
- The effect of detector nonlinearity on WFIRST PSF profiles for weak gravitational lensing measurements
- Weak Gravitational Lensing Systematics from Image Combination
- Initial results from a laboratory emulation of weak gravitational lensing measurements
Cited by in corpus (21)
- Weak lensing for precision cosmology
- NIRCam Performance on JWST In Flight
- Laboratory measurement of the brighter-fatter effect in an H2RG infrared detector
- The Brighter-Fatter Effect in the JWST MIRI Si:As IBC detectors I. Observations, impact on science, and modelling
- A Synthetic Roman Space Telescope High-Latitude Imaging Survey: Simulation Suite and the Impact of Wavefront Errors on Weak Gravitational Lensing
- Brighter-fatter effect in near-infrared detectors -- I. Theory of flat auto-correlations
- JWST NIRCam Defocused Imaging: Photometric Stability Performance and How it Can Sense Mirror Tilts
- Brighter-fatter effect in near-infrared detectors -- II. Auto-correlation analysis of H4RG-10 flats
- Constraining the Mass of the Emerging Galaxy Cluster SpARCS1049+56 at z=1.71 with Infrared Weak Lensing
- Brighter-fatter effect in near-infrared detectors -- III. Fourier-domain treatment of flat field correlations and application to WFIRST
- Instrument Simulator and Data Reduction Pipeline for the iLocater Spectrograph
- Is Flat Fielding Safe for Precision CCD Astronomy?
- An Algorithm to Mitigate Charge Migration Effects in Data from the Near Infrared Imager and Slitless Spectrograph on the James Webb Space Telescope
- StarDICE I: sensor calibration bench and absolute photometric calibration of a Sony IMX411 sensor
- Assessing the Suitability of H4RG Near Infrared Detectors for Precise Doppler Radial Velocity Measurements
- Intra-pixel response characterization of a HgCdTe near infrared detector with a pronounced crosshatch pattern
- Precision Projector Laboratory: Detector Characterization with an Astronomical Emulation Testbed
- Impact of Image Persistence in the Roman Space Telescope High-Latitude Survey
- Spot-Based Measurement of the Brighter-Fatter Effect on a Roman Space Telescope H4RG Detector and Comparison with Flat-Field Data
- Euclid preparation. Overview of Euclid infrared detector performance from ground tests
- A Classic Nonlinearity Correction Algorithm for Detectors Read Out Up-The-Ramp