Surface Brightness Correction for Compact Extended Sources Observed by the AKARI Far-Infrared Surveyor (FIS) in the Slow-Scan Mode
arXiv:1611.07160 · doi:10.1093/pasj/psw115
Abstract
We present a general surface brightness correction method for compact extended sources imaged in the slow-scan pointed observation mode of the Far-Infrared Surveyor (FIS) aboard the AKARI Infrared Astronomical Satellite. Our method recovers correct surface brightness distribution maps by re-scaling archived raw FIS maps using the surface-brightness-dependent inverse FIS response function. The flux of a target source is then automatically corrected for as the simple sum of surface brightnesses within the adopted contour encircling the perimeter of the target (i.e., contour photometry). This correction method is contrasted to the previous aperture photometry method for point sources, which directly corrects for the target flux with a flux-dependent scaling law. The new surface brightness correction scheme is applicable to objects of any shape from unresolved point sources to resolved extended objects, as long as the target is not deemed diffuse, i.e., the total extent of the target source does not exceed too much more than a single FIS scan width of 10 arcmin. The new correction method takes advantage of the well-defined shape (i.e., the scale invariance) of the point-spread function, which enables us to adopt a power-law FIS response function. We analyze the point-source photometric calibrator data using the FIS AKARI Slow-scan Tool (FAST) and constrained the parameters of the adopted power-law FIS response function. We conclude that the photometric accuracy of the new correction method is better than 10% error based on comparisons with the expected fluxes of the photometric calibrators and that resulting fluxes without the present correction method can lead up to 230% overestimates or down to 50% underestimates.
accepted for publication in PASJ
References in corpus (21)
- Herschel Space Observatory - An ESA facility for far-infrared and submillimetre astronomy
- The Photodetector Array Camera and Spectrometer (PACS) on the Herschel Space Observatory
- The Infrared Astronomical Mission AKARI
- Spectral Irradiance Calibration in the Infrared. XIV: the Absolute Calibration of 2MASS
- The Far-Infrared Surveyor (FIS) for AKARI
- Scanamorphos: a map-making software for Herschel and similar scanning bolometer arrays
- Absolute Calibration and Characterization of the Multiband Imaging Photometer for Spitzer. II. 70 micron Imaging
- The Herschel-ATLAS Data Release 1 Paper I: Maps, Catalogues and Number Counts
- Spectral Irradiance Calibration in the Infrared. XIII. "Supertemplates" and On-Orbit Calibrators for SIRTF's Infrared Array Camera (IRAC)
- MESS (Mass-loss of Evolved StarS), a Herschel Key Program
- Detection of the Cosmic Far-Infrared Background in the AKARI Deep Field South
- The Far-Infrared All-Sky Survey Maps
- AKARI/FIS Mapping of the ISM-Wind Bow Shock around Alpha Ori
- Large-scale distributions of mid- and far-infrared emission from the center to the halo of M82 revealed with AKARI
- Calibration and Performance of the AKARI Far-Infrared Surveyor (FIS) -- Slow-Scan Observation Mode for Point Sources
- Calibration of the AKARI Far-infrared All Sky Survey Maps
- The Herschel Planetary Nebula Survey (HerPlaNS) I. Data Overview and Analysis Demonstration with NGC 6781
- Far-Infrared Properties of Blue Compact Dwarf Galaxies Observed with AKARI/Far-Infrared Surveyor (FIS)
- Far-infrared imaging of post-AGB stars and (proto)-planetary nebulae with the AKARI Far-Infrared Surveyor
- AKARI Far-Infrared Source Counts in the Lockman Hole
- Far-infrared distributions in nearby spiral galaxies NGC2841 and NGC2976 observed with AKARI/FIS