Measurement of the low-energy quenching factor in germanium using an Y/Be photoneutron source
arXiv:1608.03588 · doi:10.1103/PhysRevD.94.122003
Abstract
We employ an Y/Be photoneutron source to derive the quenching factor for neutron-induced nuclear recoils in germanium, probing recoil energies from a few hundred eV to 8.5keV. A comprehensive Monte Carlo simulation of our setup is compared to experimental data employing a Lindhard model with a free electronic energy loss and an adiabatic correction for sub-keV nuclear recoils. The best fit obtained using a Monte Carlo Markov Chain (MCMC) ensemble sampler is in good agreement with previous measurements, confirming the adequacy of the Lindhard model to describe the stopping of few-keV ions in germanium crystals at a temperature of 77 K. This value of corresponds to a quenching factor of 13.7 % to 25.3 % for nuclear recoil energies between 0.3 keV and 8.5 keV, respectively.
arXiv comment7 pages, 6 figures
References in corpus (19)
- emcee: The MCMC Hammer
- Results from a Search for Light-Mass Dark Matter with a P-type Point Contact Germanium Detector
- CoGeNT: A Search for Low-Mass Dark Matter using p-type Point Contact Germanium Detectors
- Large-Mass Ultra-Low Noise Germanium Detectors: Performance and Applications in Neutrino and Astroparticle Physics
- Experimental constraints on a dark matter origin for the DAMA annual modulation effect
- A Consistent Dark Matter Interpretation For CoGeNT and DAMA/LIBRA
- Dark Matter Search Results from the PICO-60 CFI Bubble Chamber
- Characterization and Performance of Germanium Detectors with sub-keV Sensitivities for Neutrino and Dark Matter Experiments
- Measurement of the ionization produced by sub-keV silicon nuclear recoils in a CCD dark matter detector
- Applications of an Y-88/Be photo-neutron calibration source to Dark Matter and Neutrino Experiments
- Atomic limits in the search for galactic dark matter
- Development of Bubble Chambers With Enhanced Stability and Sensitivity to Low-Energy Nuclear Recoils
- Neutron Inelastic Scattering Processes as Background for Double-Beta Decay Experiments
- Measurement of the response of heat-and-ionization germanium detectors to nuclear recoils
- Ionization Efficiency Study for Low Energy Nuclear Recoils in Germanium
- A reanalysis of radioisotope measurements of the BeBe cross-section
- New libraries for simulating neutron scattering in dark matter detector calibrations
- Contribution of the electron-phonon interaction to Lindhard energy partition at low energy in Ge and Si detectors for astroparticle physics applications
- Impact of Low-Energy Response to Nuclear Recoils in Dark Matter Detectors
Cited by in corpus (36)
- Observation of Coherent Elastic Neutrino-Nucleus Scattering
- Direct Detection of WIMP Dark Matter: Concepts and Status
- Projected Sensitivity of the SuperCDMS SNOLAB experiment
- Low-Mass Dark Matter Search with CDMSlite
- Limits on Light Weakly Interacting Massive Particles from the First 102.8 kg day Data of the CDEX-10 Experiment
- Constraints on elastic neutrino nucleus scattering in the fully coherent regime from the CONUS experiment
- Solar Neutrinos as a Signal and Background in Direct-Detection Experiments Searching for Sub-GeV Dark Matter With Electron Recoils
- The Migdal Effect and Photon Bremsstrahlung in effective field theories of dark matter direct detection and coherent elastic neutrino-nucleus scattering
- Germanium response to sub-keV nuclear recoils: a multipronged experimental characterization
- Novel constraints on neutrino physics beyond the standard model from the CONUS experiment
- A Dark Matter Interpretation of Excesses in Multiple Direct Detection Experiments
- Neutron-induced background in the CONUS experiment
- Direct measurement of the ionization quenching factor of nuclear recoils in germanium in the keV energy range
- Response of CsI[Na] to Nuclear Recoils: Impact on Coherent Elastic Neutrino-Nucleus Scattering (CENS)
- First results of the nuGeN experiment on coherent elastic neutrino-nucleus scattering
- Direct Detection Limits on Heavy Dark Matter
- Detecting Beyond the Standard Model Interactions of Solar Neutrinos in Low-Threshold Dark Matter Detectors
- Ultra-Heavy Dark Matter Search with Electron Microscopy of Geological Quartz
- Mapping The Neutrino Floor For Dark Matter-Electron Direct Detection Experiments
- Physics implications of recent Dresden-II reactor data
- Study of the ionization efficiency for nuclear recoils in pure crystals
- Large-size sub-keV sensitive germanium detectors for the CONUS experiment
- Dark matter detectors as a novel probe for light new physics
- Exotic Dark Matter Search with CDEX-10 Experiment at China's Jinping Underground Laboratory
- First experimental constraints on WIMP couplings in the effective field theory framework from CDEX
- Response of undoped cryogenic CsI to low-energy nuclear recoils
- Ionization yield measurement in a germanium CDMSlite detector using photo-neutron sources
- Full background decomposition of the CONUS experiment
- Ionisation quenching factors from W-values in pure gases for rare event searches
- Updated Constraints on the Dark Matter Interpretation of CDMS-II-Si Data
- First observation of isolated nuclear recoils following neutron capture for dark matter calibration
- New constraints on coherent elastic neutrino-nucleus scattering by the nuGeN experiment
- Gusts in the Headwind: Uncertainties in Direct Dark Matter Detection
- Neutron capture-induced silicon nuclear recoils for dark matter and CENS
- Intrinsic Fano factor of nuclear recoils for dark matter searches
- Constraints on dark matter boosted by supernova shock within the effective field theory framework from the CDEX-10 experiment