Geometric calibration of the SND detector electromagnetic calorimeter
arXiv:1606.00571 · doi:10.1016/j.nima.2016.11.071
Abstract
This paper presents the design, implementation and validation of the software alignment procedure used to perform geometric calibration of the electromagnetic calorimeter with respect to the tracking system of the SND detector which is taking data at the VEPP-2000 e^{+}e^{-}collider (BINP, Novosibirsk). This procedure is based on the mathematical model describing the relative calorimeter position. The parameter values are determined by minimizing a χ^{2} function using the difference between particle directions reconstructed in these two subdetectors for e^{+}e^{-}\rightarrow e^{+}e^{-} scattering events. The results of the calibration applied to data and MC simulation fit the model well and give an improvement in particle reconstruction. They are used in data reconstruction and MC simulation.
arXiv comment17 pages, 10 figures
References in corpus (7)
- Big-Bang Nucleosynthesis
- Electron performance measurements with the ATLAS detector using the 2010 LHC proton-proton collision data
- Spherical Neutral Detector for VEPP-2M collider
- Study of e+e- --> omega pi0 --> pi0 pi0 gamma in the energy range 1.05--2.00 GeV with SND
- Search for the decay with the SND detector
- The BaBar Electromagnetic Calorimeter: Status and Performance Improvements
- Measurement of the nuclear interaction length in the NaI(Tl) calorimeter