Single electron multiplication distribution in GEM avalanches
arXiv:1605.06939 · doi:10.1088/1748-0221/11/10/P10017
Abstract
In this paper, measurement results and experimental methodology are presented on the determination of multiplication distributions of avalanches initiated by single electron in GEM foils. The measurement relies on the amplification of photoelectrons by the GEM under study, which is subsequently amplified in an MWPC for signal enhancement and readout. The intrinsic detector resolution, namely the sigma-over-mean ratio of the multiplication. distribution is also elaborated. Small gain dependence of the shape of the avalanche response distribution is observed in the range of net effective gain of 15 to 100. The distribution has an exponentially decaying tail at large amplitudes. At small amplitudes, the applied working gas is seen to have a well visible effect on the shape of the multiplication distribution. Equivalently, the working gas has an influence on the intrinsic detector resolution of GEMs via suppression of the low amplitude responses. A sigma-over-mean ratio of 0.75 was reached using a neon based mixture, whereas other gases provided an intrinsic detector resolution closer to 1, meaning a multiplication distribution closer to the low-field limit exponential case.
27 pages, 18 figures
References in corpus (2)
Cited by in corpus (4)
- Charge density as a driving factor of discharge formation in GEM-based detectors
- Performance of the CMS Zero Degree Calorimeters in pPb collisions at the LHC
- Ion backflow studies with a triple-GEM stack with increasing hole pitch
- A novel technique for the measurement of the avalanche fluctuations of a GEM stack using a gating foil