Cryogenic resonator design for trapped ion experiments in Paul traps
arXiv:1601.06699 · doi:10.1007/s00340-016-6430-z
Abstract
Trapping ions in Paul traps requires high radio-frequency voltages, which are generated using resonators. When operating traps in a cryogenic environment, an in-vacuum resonator showing low loss is crucial to limit the thermal load to the cryostat. In this study, we present a guide for the design and production of compact, shielded cryogenic resonators. We produced and characterized three different types of resonators and furthermore demonstrate efficient impedance matching of these resonators at cryogenic temperatures.
arXiv comment13 pages, 12 figures, 1 table
References in corpus (9)
- Experimental issues in coherent quantum-state manipulation of trapped atomic ions
- 14-qubit entanglement: creation and coherence
- Effective quantum spin systems with ion traps
- Observation of entanglement propagation in a quantum many-body system
- Heating of trapped ions from the quantum ground state
- Suppression of Heating Rates in Cryogenic Surface-Electrode Ion Traps
- Absolute frequency measurement of the 40Ca+ S1/2 - D5/2 clock transition
- On the application of radio frequency voltages to ion traps via helical resonators
- Compact RF resonator for cryogenic ion traps
Cited by in corpus (7)
- Quantum information processing with superconducting circuits: a review
- Microwaves in Quantum Computing
- State Readout of a Trapped Ion Qubit Using a Trap-Integrated Superconducting Photon Detector
- Cryogenic setup for trapped ion quantum computing
- Two-dimensional linear trap array for quantum information processing
- Micromotion-enabled improvement of quantum logic gates with trapped ions
- An ultralow-noise superconducting radio-frequency ion trap for frequency metrology with highly charged ions