A torsion balance for probing a non-standard force in the sub-micrometre range
arXiv:1508.07259 · doi:10.1088/0264-9381/24/16/001
Abstract
We report the performance of an instrument that employs a torsion balance for probing a non-standard force in the sub-micrometre range. High sensitivity is achieved by using a torsion balance that has a long torsional period, strong magnetic damping of all vibrational motions and a feedback system that employs an optical lever. In torsion balance experiments, the distance fluctuations during measurements and the accuracy to which the absolute distance is determined are crucial for determining the sensitivity of the balance to a macroscopic force in the sub-micrometre range. We have estimated the root mean square amplitude of the distance fluctuation to be 18 nm by considering the effects due to seismic motions, tilt motions, residual angular fluctuations and thermal fluctuations. We have also estimated the error of the absolute distance to be 13 nm and the statistical error of the force to be 3.410 N by measuring the electrostatic forces. As a result of this systematic study, we have evaluated the sensitivity of the balance to both a non-standard force and to the Casimir force.
arXiv comment13 pages, 5 figures
References in corpus (28)
- An Alternative to Compactification
- The Hierarchy Problem and New Dimensions at a Millimeter
- Phenomenology, Astrophysics and Cosmology of Theories with Sub-Millimeter Dimensions and TeV Scale Quantum Gravity
- New Developments in the Casimir Effect
- Precision Measurement of the Casimir Force from 0.1 to 0.9 microns
- Measurement of the Casimir force between parallel metallic surfaces
- Weak Scale Superstrings
- An exotic class of Kaluza-Klein models
- Improved Precision Measurement of the Casimir Force Using Gold Surfaces
- Precise comparison of theory and new experiment for the Casimir force leads to stronger constraints on thermal quantum effects and long-range interactions
- Measurement of the Casimir force between dissimilar metals
- Template-stripped gold surfaces with 0.4 nm rms roughness suitable for force measurements. Application to the Casimir force in the 20-100 nm range
- Millimetre-Range Forces in Superstring Theories with Weak-Scale Compactification
- New Experimental Constraints on Non-Newtonian Forces below 100 microns
- Constraining New Forces in the Casimir Regime Using the Isoelectronic Technique
- Temperature dependence of the Casimir effect between metallic mirrors
- Macroscopic Forces from Supersymmetry
- Violation of the Nernst heat theorem in the theory of thermal Casimir force between Drude metals
- Casimir force at both non-zero temperature and finite conductivity
- Deviations from the Newton law due to extra dimensions
- Constraints for hypothetical interactions from a recent demonstration of the Casimir force and some possible improvements
- Surface-impedance approach solves problems with the thermal Casimir force between real metals
- New origin for approximate symmetries from distant breaking in extra dimensions
- Temperature dependence of the Casimir force between real metals: problems and approach to their resolution
- Thermal noise limitations to force measurements with torsion pendulums: Applications to the measurement of the Casimir force and its thermal correction
- Linear in temperature correction to the Casimir force
- Development of a high sensitivity torsional balance for the study of the Casimir force in the 1-10 micrometer range
- Extra Dimensions at the Weak Scale and Deviations from Newtonian Gravity