Extraction Method of Fine Granular Performance from Scintillator Strip Electromagnetic Calorimeter
arXiv:1405.4456 · doi:10.1016/j.nima.2015.04.001
Abstract
We describe an algorithm which has been developed to extract fine granularity information from an electromagnetic calorimeter with strip-based readout. Such a calorimeter, based on scintillator strips, is being developed to apply particle flow reconstruction to future experiments in high energy physics. Tests of this algorithm in full detector simulations, using strips of size 45 x 5 mm^2 show that the performance is close to that of a calorimeter with true 5 x 5 mm^2 readout granularity. The performance can be further improved by the use of 10 x 10 mm^2 tile- shaped layers interspersed between strip layers.
arXiv comment11 pages, 10 figures
References in corpus (5)
- Particle Flow Calorimetry and the PandoraPFA Algorithm
- Design and Electronics Commissioning of the Physics Prototype of a Si-W Electromagnetic Calorimeter for the International Linear Collider
- Performance of the first prototype of the CALICE scintillator strip electromagnetic calorimeter
- The Pandora Particle Flow Algorithm
- Performance of the CALICE Scintillator-Based ECAL Depending on the Temperature
Cited by in corpus (4)
- A Few-Degree Calorimeter for the future Electron-Ion Collider
- Leveraging Staggered Tessellation for Enhanced Spatial Resolution in High-Granularity Calorimeters
- Optimization study of scintillator shape of electromagnetic calorimeter for Higgs factories
- SiPM Dynamic Range for CEPC Scintillator-based Electromagnetic Calorimeter