A widely tunable 10-m quantum cascade laser phase-locked to a state-of-the-art mid-infrared reference for precision molecular spectroscopy
arXiv:1404.1162 · doi:10.1063/1.4886120
Abstract
We report the coherent phase-locking of a quantum cascade laser (QCL) at 10-m to the secondary frequency standard of this spectral region, a CO2 laser stabilized on a saturated absorption line of OsO4. The stability and accuracy of the standard are transferred to the QCL resulting in a line width of the order of 10 Hz, and leading to our knowledge to the narrowest QCL to date. The locked QCL is then used to perform absorption spectroscopy spanning 6 GHz of NH3 and methyltrioxorhenium, two species of interest for applications in precision measurements.
arXiv comment5 pages, 4 figures
References in corpus (19)
- Mid-infrared frequency combs
- Order of Magnitude Smaller Limit on the Electric Dipole Moment of the Electron
- Cold Molecule Spectroscopy for Constraining the Evolution of the Fine Structure Constant
- Progress in Atomic Fountains at LNE-SYRTE
- Stability of the proton-to-electron mass ratio
- Using Molecules to Measure Nuclear Spin-Dependent Parity Violation
- Observing the intrinsic linewidth of a quantum-cascade laser: beyond the Schawlow-Townes limit
- Progress toward a first observation of parity violation in chiral molecules by high-resolution laser spectroscopy
- A search for varying fundamental constants using Hz-level frequency measurements of cold CH molecules
- Probing weak force induced parity violation by high resolution mid-infrared molecular spectroscopy
- Optical spectrum analyzer with quantum limited noise floor
- Progress towards an accurate determination of the Boltzmann constant by Doppler spectroscopy
- Determination of the Boltzmann constant by laser spectroscopy as a basis for future measurements of the thermodynamic temperature
- Narrow-line phase-locked quantum cascade laser in the 9.2 micron range
- Mid-infrared laser phase-locking to a remote near-infrared frequency reference for high precision molecular spectroscopy
- A revised uncertainty budget for measuring the Boltzmann constant using the Doppler Broadening Technique on ammonia
- High resolution spectroscopy of methyltrioxorhenium: towards the observation of parity violation in chiral molecules
- Robust, frequency-stable and accurate mid-IR laser spectrometer based on frequency comb metrology of quantum cascade lasers up-converted in orientation-patterned GaAs
- HCOOH high resolution spectroscopy in the 9.18m region
Cited by in corpus (17)
- Quantum cascade laser frequency stabilisation at the sub-Hz level
- QCL-based frequency metrology from the mid-infrared to the THz range: a review
- High-precision methanol spectroscopy with a widely tunable SI-traceable frequency-comb-based mid-infrared QCL
- A quantum cascade laser-based mid-IR frequency metrology system with ultra-narrow linewidth and -level frequency instability
- Measuring the Boltzmann constant by mid-infrared laser spectroscopy of ammonia
- Towards detection of the molecular parity violation in chiral Ru(acac) and Os(acac)
- Absorption line shape recovery beyond the detection bandwidth limit: application to the precision spectroscopic measurement of the Boltzmann constant
- High-resolution mid-infrared spectroscopy of buffer-gas-cooled methyltrioxorhenium molecules
- Quantum cascade laser-pumped terahertz molecular lasers: frequency noise and phase-locking using a 1560nm frequency comb
- Highly coherent phase-lock of an 8.1 m quantum cascade laser to a turn-key mid-IR frequency comb
- Linear probing of molecules at micrometric distances from a surface with sub-Doppler frequency resolution
- Heterodyne coherent detection of phase modulation in a mid-infrared unipolar device
- Near-to mid-IR spectral purity transfer with a tunable frequency comb: methanol frequency metrology over a record frequency span
- Laser spectroscopy of cold molecules
- Ultra-sensitive heterodyne detection at room temperature in the atmospheric windows
- Studying fundamental physics using quantum enabled technologies with trapped molecular ions
- Wavelength modulation laser spectroscopy of NO at 17 m