The OLYMPUS Internal Hydrogen Target
arXiv:1404.0579 · doi:10.1016/j.nima.2014.04.029
Abstract
An internal hydrogen target system was developed for the OLYMPUS experiment at DESY, in Hamburg, Germany. The target consisted of a long, thin-walled, tubular cell within an aluminum scattering chamber. Hydrogen entered at the center of the cell and exited through the ends, where it was removed from the beamline by a multistage pumping system. A cryogenic coldhead cooled the target cell to counteract heating from the beam and increase the density of hydrogen in the target. A fixed collimator protected the cell from synchrotron radiation and the beam halo. A series of wakefield suppressors reduced heating from beam wakefields. The target system was installed within the DORIS storage ring and was successfully operated during the course of the OLYMPUS experiment in 2012. Information on the design, fabrication, and performance of the target system is reported.
9 pages, 13 figures
References in corpus (1)
Cited by in corpus (7)
- Two-photon exchange in elastic electron-proton scattering
- Hard Two-Photon Contribution to Elastic Lepton-Proton Scattering: Determined by the OLYMPUS Experiment
- Measurement of two-photon exchange effect by comparing elastic cross sections
- Operation and characterization of a windowless gas jet target in high-intensity electron beams
- QED Radiative Corrections to Low-Energy Moller and Bhabha Scattering
- Measurement of the Charge-Averaged Elastic Lepton-Proton Scattering Cross Section by the OLYMPUS Experiment
- Design and Operation of a Windowless Gas Target Internal to a Solenoidal Magnet for Use with a Megawatt Electron Beam