Three mode interaction noise in laser interferometer gravitational wave detectors
arXiv:1403.1670 · doi:10.1088/0264-9381/31/14/145002
Abstract
Triply resonant three mode interactions in long optical cavities have been shown to lead to enhanced scattering of carrier light by the ultrasonic acoustic modes of the test mass mirrors. At high optical power, this can lead to parametric instability (parametric gain R > 1) for a few acoustic modes with strong spectral and spatial overlap. Numerous ?~10^3 acoustic modes of the test masses are predicted to have R > 10^2. Experimental studies have shown that such modes also strongly scatter the carrier light, enabling very sensitive readout of the acoustic modes. The 3-mode scattering from the thermal fluctuation of large population of ultrasonic modes would causes random changes in occupation number of the carrier light and cavity transverse optical modes. Because the thermal fluctuation time scale (set by the acoustic mode relaxation times) is typically a few seconds, the noise spectrum from thermally induced photon number fluctuations is strongly peaked at low frequency. The noise level depends on the acoustic mode structure and acoustic losses of the test masses, the transverse optical mode spectrum of the optical cavities and on the test mass temperature. We theoretically investigate the possible effect of this noise and show that in advanced detectors under construction three mode interaction noise is below the standard quantum limit, but could set limits on future low frequency detectors that aim to exceed the free mass standard quantum limit.
arXiv comment20 pages, 5 figures, submitted to Class. Quan. Grav
References in corpus (12)
- Detector configuration of KAGRA - the Japanese cryogenic gravitational-wave detector
- Conversion of conventional gravitational-wave interferometers into QND interferometers by modifying their input and/or output optics
- Parametric Oscillatory Instability in Fabry-Perot (FP) Interferometer
- Quantum Measurement Theory in Gravitational-Wave Detectors
- Experimental demonstration of a non-destructive controlled-NOT quantum gate for two independent photon-qubits
- Analysis of Parametric Oscillatory Instability in Power Recycled LIGO Interferometer
- Full mechanical characterization of a cold damped mirror
- A General Approach to Optomechanical Parametric Instabilities
- Optical noise correlations and beating the standard quantum limit in advanced gravitational-wave detectors
- Damping parametric instabilities in future gravitational wave detectors by means of electrostatic actuators
- Quantum ground-state cooling and tripartite entanglement with three-mode optoacoustic interactions
- Radiation pressure excitation of test mass ultrasonic modes via three mode opto-acoustic interactions in a suspended Fabry-Perot cavity